Safety
Warning! This equipment produces high voltages that can be very dangerous.
Assemble the entire setup before powering up the device.
• Power supply enclosure is to be protectively grounded via provided grounding stud.
• Use low voltage power supply with DC output galvanically insulated from AC input
(insulation strength 4000VAC, 2500VAC or 1500VAC is selected in dependence on your
application)
• Do not connect / disconnect output cables while driver is turned on
• Do not operate with disconnected load
• Avoid casual contacts of personnel with output cables and with the load
• Do not turn the power supply on if it was already damaged with water, chemicals,
mechanical or electrical shock
• Do not self-repair the power supply, there are no user-serviceable parts inside
Operations
1 Ensure 24V DC (48V DC) power supply is off
2 Connect PBZ-300 (PBZ-500) to the load and to 24V DC (48V DC)
power supply. Do not apply DC power until the setup is completely
assembled
3 Disable PBZ-300 (PBZ-500) (pin 7 of Interface)
4 Set HV Program to 0V (pins 3 and 4 of Interface)
5 Apply 24V DC (48V DC) power to PBZ-300 (PBZ-500)
6 Set HV Program to the desired value (pins 3 and 4 of Interface)
7 Enable PBZ-300 (pin 7 of Interface)
Be careful around the equipment.