10 kw - 29 kw, total heat recovery reversible multi-purpose heat pumps - dc inverter (40 pages)
Summary of Contents for Galletti MCI
Page 1
POMPE À CHALEUR À CYCLE AIR /EAU Manuel d’installation LUFT/WASSER-WÄRMEPUMPE Installationanweisungen POMPA DI CALORE ARIA / ACQUA Manuale d’installazione BOMBA DE CALOR CICLO DE AIRE/AGUA Manual de instalación LUCHT/WATERCYCLUS WARMTEPOMP Montagehandleiding MCI Reversible Inverter Heat Pump verter A + class technology RG66012647 Original document...
Page 10
Ν Ν 1 8 1 0 1 1 1 2 4 5 1 6 MCI__H C W G Y 13 14 15 7 6 1 8 21 23 24 33ΑW−CS1 Remote control Remote control Ν Ν 1 8 1 0 1 1 1 2 4 5 1 6 MCI__X 33ΑW−CS1...
Page 11
Line filter for water (10 mesh/cm^2) Position 4 LED Inverter Diagnostics Opening cable knockouts Pressure gauges Removing front panel Board (only MCI 012_ and MCI 015_) Filling valve Drain hose and base pan knockouts Position LED GMC Diagnostics Board System drain valve...
Page 12
DEUTSCH Abbildungen und Legende: Gerät MCI__X (nur für MCI012_) Maße Absperrventile Position 4 LED Diagnose Platine Freiräume (Installation von 1 Gerät) Wasserleitungsfilter (10 Maschen/ Inverter (nur MCI012_ und MCI015_) Freiräume (Installation von mehreren Geräten) cm^2) Position LED Diagnose Platine GMC Öffnungsprozedur der Rohrdurchgänge Wasserumwälzpumpe Installations-Klemmenleiste...
Page 13
ESPAÑOL Títulos de figuras y leyendas: Dimensiones unidad MCI__X Caída de presión (kPa) Espacios libres (instalación de 1 unidad) Válvulas de cierre 16 Posición placas - Códigos alarmas placa Espacios libres (instalación de varias unidades) Filtro de línea para agua (10 mallas/ Convertidor (sólo para MCI012_) Procedimiento de apertura de los pasos de los cm^2)
Air / Water Cycle Heat Pump 1 - INTRODUCTION Contents Page INSTALLATION 1.1 - R-410A - General info R-410A - General info ............Safety procedures ..............• This air conditioner adopts the new HFC refrigerant Dimensions and clearances..........(R410A) which does not destroy ozone layer. SITING THE UNIT •...
2 - SAFETY PROCEDURES 2.2 - Units handling Important safety information is displayed on the product Ensure adequate personal protective equipment is used. and in this Manual. Please read this installation manual carefully before installing the unit. Inspect equipment for damage due to improper transportation or handling: File an immediate claim with It contains further important instructions for proper the shipping company.
2.4 - Electrical connections WARNING • Be sure to provide grounding; inappropriate grounding All field electrical connections are the responsibility of the may cause electric shock. installer. • Do not connect ground wires to gas pipes, water pipes, lightning rods or ground wires for telephone cables. DANGER DANGER: Electrical shock can cause severe personal injury or death.
3 - DIMENSIONS AND CLEARANCES For dimensions see fig. 1 004_ 1Ph 006_ 1Ph 008_ 1Ph 012_1Ph 1363 015_1Ph 1363 012_3Ph 1363 015_3Ph 1363 Minimum installation clearances in mm are shown in fig.2 (single installation) and fig. 3 (serial installation) NOTE: The height of the obstacle at both front and rear side should be lower than the height of the outdoor unit.
5.5 - Hydronic module (Fig. 9/10/11) the water circuit inside the unit. The MCI__H units are equipped with an integrated Refer to Figure 9 for the exact connection of the water hydronic module with a variable flows pump self-controlled pipes. Figures 10 and 11 describe the integrated components that allows fast installation with the aid of a few external in their various configurations.
NOTE: The discharge of the safety valve can be channelled to the outside of the machine using the pre-cut holes (see Anti-seizing pump Fig. 4). In this case, it is necessary to provide an open drain The MCI__H units are equipped with protection against the funnel.
Pipe water content Unit Internal Diameter Outer diameter Liters / meter 004_ 006_ 008_ 012_ 015_ 12 mm 14 mm 0.11 l/m 0.20 0.28 0.33 0.58 0.69 Nominal water flow 14 mm 16 mm 0.15 l/m Water content 16 mm 18 mm 0.20 l/m Copper...
7 - ELECTRICAL CONNECTIONS (FIG. 17) Make ground connection prior to any other electrical All field electrical connections are the responsibility of the connections. installer. WARNING: Make water connections before electrical connections. Unit Power supply V- ph - Hz 230 - 1 -50 400 - 3N - 50 Allowable Voltage Range 207 ÷...
8.1 - 3-way valve (PINS: 5-N, NUI CODE:147) The MCI units drive a 3-way valve to manage a sanitary water Several outputs are used for more than one condition. It storage tank. The operating logic provides that, in case of a...
8.7 - Signal for requesting an External Heat Source (EHS) 8.8 - External water circulator for MCI__X unit Between PINS 4 and N of the terminal strip (see Fig. 17), there Units without an integrated pump allow driving an external is an output (1ph ~ 230V, 2A max) that can be programmed one.
9.2 - Inverter board alarm codes (only for sizes 015 1Ph and 012-015 3Ph) (Fig. 16) If there is an error, any of LED D800 to D804 goes on. The error which is generating at present and the latest error (Display 1) (latest error information including present) can be confirmed When pushing the pushdown button switch SW800 for...
9.3 - GMC Board alarm codes (Fig. 16) 10 - UNIT PROTECTION DEVICES There is an LED on the GMC board that displays any board Type of safety device Switch on pressure Release errors. Pressure switch on water 300kPa N.A. Anti-Freeze Protection Adjustable from 3 to 9 °C software controlled...