Advertisement

Quick Links

TEKRA CT
MANUAL
Instructions for use
New Age Italia srl
Via De Brozzi, 3 - 48022 Lugo (RA)
Tel.:+39-0545.32019 - Telefax: +39-0545.369028
Web:
www.newageitalia.it
- E-mail:
info@newageitalia.it
This document is property of New Age Italia srl. All rights are reserved. Any copy or
reproduction of it through any means, including total or partial photocopy of the contents, is
prohibited without the written consent of New Age Italia srl.

Advertisement

Table of Contents
loading

Summary of Contents for New Age TEKRA CT

  • Page 1 - E-mail: info@newageitalia.it This document is property of New Age Italia srl. All rights are reserved. Any copy or reproduction of it through any means, including total or partial photocopy of the contents, is prohibited without the written consent of New Age Italia srl.
  • Page 2 2/16 Rev. 00 del 12/03/10...
  • Page 3: Table Of Contents

    Cap.1 – PRESENTATION ..............5 1.1 – What is TEKRA CT? ..............5 1.2 Why use TEKRA CT? ..............5 1.3 – Who is TEKRA CT for? ............. 5 1.4 – Indications................5 1.5 – Contraindications ..............6 Cap.2 –OPERATION ................7 2.1 –...
  • Page 4 Cap.9 – WARNINGS ................ 14 Cap.10 – TECHNICAL FEATURES ............. 14 10.1 – Power supply..............14 10.2 – Output features ..............15 10.3 – Other features ..............15 Cap.11 – BASIC SUPPLY AND ACCESSORIES ......... 15 11.1 – Basic supply ............... 15 11.1 –...
  • Page 5: Cap.1 - Presentation

    1 . 3 – W h o i s T E K R A C T f o r ? The medical field (especially physiotherapy) is the sector most suited for TEKRA CT to fully express its potentialities. – INDICATIONS AND CONTRAINDICATIONS 1 .
  • Page 6: Contraindications

    We recommend consulting a doctor for the diagnosis and control of the therapy. 1 . 5 – C o n t r a i n d i c a t i o n s Magnetic fields have some contraindications in common with other physical equipment which acts by means of endogenous heat production: ...
  • Page 7: Cap.2 -Operation

    C a p . 2 – O P E R A T I O N 7-Stop button 1-Display touch screen 2- Knob + push button 3-Capacitive reference plate outlet 4- Capacitive active electrode outlet 1 – Display TOUCH SCREEN 4 – Capacitive active electrode outlet 2 –...
  • Page 8: Turning Device On

    – T u r n i n g d e v i c e o n Press the rear switch to turn TEKRA CT on. An initial screen appears on the display presenting the device including: the name of the appliance version, the START key and the CONFIGURE key.
  • Page 9: Setting Time And Intensity Of Emission

    5) unblocking code: to enter before turning the device on the first time C a p . 3 – P R E S E T P R O G R A M S TEKRA CT has 35 preset programs and 20 free protocols. Preset programs are listed in the chart below: Rev.
  • Page 10 PROGRAM TIME POWER % acne rosacea 20' CAP postherpetic neuralgia 30' CAP pyoderma, acne conglobata 30' CAP ulcer 30'CAP saphenous drainage 20' CAP Cellulitis 20' CAP Varicose veins 20' CAP Eczema 15' CAP Psoriasis 25' CAP Scars and keloids 20' CAP Dermatosis 20' CAP Scaly dermatitis...
  • Page 11: Cap.4 - Free Programs

    KNOB to set the parameter value and PRESS THE KNOB to pass from one parameter to another. Up to 3 consecutive work phases can be set with TEKRA CT. Different intensity and time values can be used in each of them. When the parameters have been set, the name of the program can be modified once again.
  • Page 12: Posture To Be Kept During The Sessions

    C a p . 6 – – P O W E R S U P P L Y TEKRA CT must be powered by the electrical mains – Precautions for use (1) Do not short-circuit the terminals.
  • Page 13: Do Not Dispose Of In Common Waste

    The useful life span of the instrument is guaranteed by the company only if maintenance is carried out regularly. N. B.: have inspections carried out only by New Age Italia. The device can be sent directly to company assistance workshops or delivered to the dealer where the device was purchased.
  • Page 14: Cap.9 - Warnings

    C a p . 9 – W A R N I N G S Pay special attention to use of the knobs in order not to jeopardise the effectiveness of the treatment. Use the device only with electrical systems compliant with Safety Standards in force.
  • Page 15: Output Features

     EN60601-1-4/A1 (2000) General requirements for safety of programmable devices.  EN 980-2003 and EN 1041 – Graphical symbols for labelling of electrical medical devices Series number (S.N) Identification code of TEKRA CT S.N. TKCT AA XXXX Identification number of device Year of manufacture C a p .
  • Page 16: Accessories And Consumption Material

    1 set of capacitive electrodes 1 power cable 1 pack of TEKRA cream 1 User manual 1 1 . 1 – A c c e s s o r i e s a n d c o n s u m p t i o n m a t e r i a l The following is the list of accessories which can be purchased apart to increase the supply of the device or to replace worn elements: - knob for capacitive therapy...

Table of Contents