Advertisement

Quick Links

ß
LASER
MANUAL
Instructions for use
New Age Italia srl
Via De Brozzi, 3 - 48022 Lugo (RA)
Tel.:+39-0545.32019 - Telefax: +39-0545.369028
Web:
www.newageitalia.it
- E-mail:
info@newageitalia.it
This document is property of New Age Italia srl. All rights are reserved. Any copy or
reproduction of it through any means, including total or partial photocopy of the contents, is
prohibited without the written consent of New Age Italia srl.

Advertisement

Table of Contents
loading

Summary of Contents for New Age Hi-Laser Beta LASER

  • Page 1 - E-mail: info@newageitalia.it This document is property of New Age Italia srl. All rights are reserved. Any copy or reproduction of it through any means, including total or partial photocopy of the contents, is prohibited without the written consent of New Age Italia srl.
  • Page 2 2/24 Rev. 00 of 14/01/10...
  • Page 3: Table Of Contents

    INDEX Cap.1 – PRESENTATION ............... 5 1.1 – Biological effects of ß LASER ........... 6 1.2 – Who is ß LASER for? ..............7 1.3 – Fields of application ..............7 1.4 – Contraindications ..............7 Cap.2 – OPERATION ................8 2.1 –...
  • Page 4 9.1 – Power supply ................17 9.2 – Output features ................17 9.3 – Output features ................17 9.4 – Other features ................17 Cap.10 – BASIC SUPPLY AND ACCESSORIES ........18 10.1 – Basic supply ................18 10.2 – Accessories and consumption material ......18 ATTENTION: ...
  • Page 5: Cap.1 - Presentation

    C a p . 1 – P R E S E N T A T I O N In 2010 New Age Italia enters the world of LASER therapy with a new aim. To have the full control of the parameters constituting LASER therapy.
  • Page 6: Biological Effects Of Ss Laser

    – B i o l o g i c a l e f f e c t s o f ß L A S E R 1 . 1 The LASER radiation, penetrating the tissues, causes photochemical reactions at cellular level that induce different effects. Mitochondrial Stimulation: one of the most therapeutical effects of the LASER, consists in stimulating cellular mitochondrion.
  • Page 7: Who Is Ss Laser For

    – W h o i s ß L A S E R f o r ? 1 . 2 The medical field (especially physiotherapy) is the sector most suited for ß LASER to fully express its potentialities. – F i e l d s o f a p p l i c a t i o n 1 .
  • Page 8: Cap.2 - Operation

    C a p . 2 – O P E R A T I O N 6-Stop button 1-Touch screen display 2- Knob + push button 3-safety key 5- Emergency Button 4- Optical fibre output NOTE: check the contraindications and follow indications carefully before applying LASER therapy.
  • Page 9: Turning Device On

    – T u r n i n g d e v i c e o n 2 . 1 To activate ß LASER, switch-on the rear switch, check that the emergency button is released, turn the switch-on key. An initial screen appears on the display presenting the device including: the name of the appliance version, the START key and the CONFIGURE key.
  • Page 10: Start Of Stimulation

    – S t a r t o f s t i m u l a t i o n 2 . 3 Once selected a pre-set program or after having regulated the parameters in the manual functioning area, the display shows START. Press the relative START to begin the therapy.
  • Page 11: Cap.3 - Pre-Set Programs

    4) Operator time out: time the operator has to press the pedal after the start key has been pressed. 5) unblocking code: to enter before turning the device on the first time 6) Maximum power output: indicates the maximum power output of the device and it’s given by the sum of the average powers of the waveforms delivered.
  • Page 12: Cap.4 - Free Programs

    NEURALGIA TENDINOPATHY POST SURGERY RESULTS BURNS OUTLINE BURNT AREA VARICOSE ULCERS OUTLINE VARICOSE ULCER AREA SORE OUTLINE SORE AREA FACIAL PARALYSIS ACNE C a p . 4 – F R E E P R O G R A M S –...
  • Page 13: Cap.5 - Applications

    C a p . 5 – A P P L I C A T I O N S – T h e r a p y s e s s i o n s 5 . 1 Apply the LASER therapy according to medical prescriptions. Applications are done every other day or 2-3 days.
  • Page 14: Posture To Be Kept During The Sessions

    red; if the operator is adjusting the bar power, then the device limits the duty cycle value showing it as red. NOTE: if the intensity set or its regulation cause excessive heating or pain in the treated zone, the intensity of the stimulation must be reduced immediately or the application must be stopped.
  • Page 15: Cap.7 - Maintenance

    The useful life span of the instrument is guaranteed by the company only if maintenance is carried out regularly. N. B.: have inspections carried out only by New Age Italia. The device can be sent directly to company assistance workshops or delivered to the dealer where the device was purchased.
  • Page 16: Cap.8 - Warnings

    C a p . 8 – W A R N I N G S Pay special attention to use of the knobs in order not to jeopardise the effectiveness of the treatment. Use the device only with electrical systems compliant with Safety Standards in force.
  • Page 17: Cap.9 - Technical Features

    C a p . 9 – T E C H N I C A L F E A T U R E S – P o w e r s u p p l y 9 . 1 Internal power supply: ROAL-MCA600 PRI: 100 - 240V ...
  • Page 18 C a p . 1 0 – B A S I C S U P P L Y A N D A C C E S S O R I E S – B a s i c s u p p l y 1 0 .

Table of Contents