Shutdown Shutting Down The Heating System For An Extended Period; Shutdown - Viessmann VITOLIGNO 300-C Operating Instructions Manual

Pellet boiler, 8 and 12 kw. heating system with ecotronic weather-compensated, digital boiler and heating circuit control unit
Table of Contents

Advertisement

Shutdown

Shutting down the heating system for an extended period
You can switch your heating system off if you do not
intend to use it. We recommend you contact your heat-
ing contractor before and after shutting down for longer
periods.
Your heating contractor can then take suitable steps,
such as frost protection for the system or heating sur-
face preservation, as required.
Shutdown
1. Note
Only disconnect the mains plug of the boiler for
maintenance and repair purposes.
The Lambda probe will otherwise not be heated
and could be damaged if the system is shut
down for a longer period.
The boiler circuit pump is switched on briefly at
regular intervals.
2. Carry out all tasks described in the overview of
chapter "Maintenance and repairs" on page 46.
3. When there is a risk of frost, drain the boiler,
observing the instructions issued by your heating
system installer or ask them to charge the system
with antifreeze.
42
Note
No special measures are required when shutting down
the system on a temporary basis.

Advertisement

Table of Contents
loading

Table of Contents