Fuel supply
Blocking times for automatic fuel supply
9.
to confirm.
d
The suction wands available for selection
will be redisplayed.
10. Repeat steps 6 to 9 to select the assignment of fur-
ther suction wands.

Purging and/or resetting suction wands

In the case of a shortage of pellets at one suction
wand, that wand will be blocked and a changeover to
the next suction wand occurs.
A blocked suction wand can be purged. A blocked
wand can also be re-enabled without prior purging. If
several wands have been preselected for purging,
these wands will be purged in sequence. Afterwards,
the system will be restarted in standard mode.
Manual purging will only commence if the boiler hop-
per is not full.
Press the following keys:
1.
for "Extended menu".
å
2.
/
for "Charging".
|
~
3.
to confirm.
d
4.
/
for "Changeover unit".
|
~
5.
to confirm.
d
The adjustable suction wands are shown.
An "X" will be shown below blocked suction
wands instead of their suction wand num-
ber.
6.
/
for selecting the suction wand.
Ù
Ú
7.
to confirm.
d
8.
/
for "Flush", "Reset" or "Reset all".
|
~
If "Flush" is selected: The suction wand
will be automatically blocked following purg-
ing.
9.
to confirm.
d
The suction wands available for selection
will be redisplayed.
10. Repeat steps 6 to 9 for purging or resetting further
suction wands.
11.
until the default display is shown (see
ä
page 14).
34
(cont.)
11.
until the default display is shown (see
ä
page 14).
Note
Check the suction wand assignment again when next
filling the pellet store and readjust the assignment if
required.