6.2.2 Cooling Circuit Connection and Filling

CAUTION
Risk of damage by using improper cooling hoses!
This may lead to damage to persons, damage to the unit or corrosion damage!
 When choosing cooling hoses pay attention to sufficient burst strength and compatibility with coolant!
 Only use cooling hoses without any signs of damage!
 In case pure water is being used as coolant, ensure that non-transparent hoses are used to prevent the
growth of algae in the water. Otherwise appropriate additives have to be used.
The cooling hoses with an internal diameter of 9 mm are connected to the unit by means of hose nipples.
Water outlet and water inlet are indicated with respective symbols.
Water supply
outlet
Water supply
inlet
Fig. 8:
Labelling of water inlet and water outletf
1)
Connect a suitable hose to the hose nipples for cooling water inlet and cooling water outlet and secure it
with a clamp, respectively.
2)
Connect a suitable hose to the hose nipples for coolant inlet and coolant outlet and secure it with a
clamp, respectively.
3)
Connect the hoses to the corresponding nipples of the device to be cooled.
PLEASE NOTE
When connecting the cooling hoses pay attention to flow direction. Follow the documentation released by
the manufacturer of the device to be cooled.
Fig. 9:
Cap of coolant container
1 Cap (version for transport is shown)