Digital converter module

Advertisement

AUDIO AND VIDEO DOOR ENTRY SYSTEM - WIRELESS MODULE
OPERATION OF THE MODULE
Operation of the CD-NEXA/BT module
The CD-NEXA/BT module provides N3301/AL and N3403/AL modules with a wireless communication interface, thereby
making it unnecessary to open the door panel to manage the phone book and programming parameters.
It is necessary to know the administrator code to connect the door panel to a PC by means of the module. To manage the
door panel, it will be necessary to download the MEMEDIT 5 program from the documentation page
https://doc.golmar.es. This program can be used to programme the door panel and back up installations to enable the
restoring of devices whose memories, due to error or fault, have been damaged.
Operating states:
See the
Description of the status LEDs
-
In standby The module will remain in standby mode whenever the door panel is not in programming mode or a
:
disconnection has occurred and 15 seconds have elapsed.
-
Waiting for connection to be established The module will remain in this mode whenever the door panel is in
programming mode. To access door panel programming mode, press the key button three times and then enter the
administrator
code.
* ( )
Note the number of digits in the configured code (factory setting 2718 = 4 digits).
-
Connection established The module has successfully established connection with the PC. If the door panel features
an N3403/AL module, the message CONNECTION RF will be displayed on the screen. In this state, it is possible to
transmit data between the door panel and the PC, thereby enabling MEMEDIT 5 to be connected to the door panel.
To establish a wireless connection with MEMEDIT 5, the module must be in the Waiting for connection to be established
state as described in the previous section, then go to Edit > Preferences:
In the new window, go to the Connection tab and select the
Then press the Search button to show the device on screen, select it with the mouse and click Connect to establish
connection with the module. If connection is successfully established, the preferences screen will automatically close
and the wireless connection light will turn blue. From this moment, it will be possible to transmit data with the door panel.
Note: If a connection code is requested, use 2718.
-
Data transmission In this state, there is active communication between the CD-NEXA/BT connection module and the
:
door
panel.
Important:
Do not press any keys on the door panel while data is being transferred between the door panel and the PC
section to differentiate each of the states.
:
Key + key + key +
:
administrator code
* ( )
2
7
1
8
Connection via CD-NEXA/BT
option
:
3
.