Kohler Mira Sport J03A Installation And User Manual

Kohler Mira Sport J03A Installation And User Manual

Hide thumbs Also See for Mira Sport J03A:

Advertisement

Quick Links

Mira Sport
7.5, 9.0, 9.8 and 10.8 kW
Installation and User Guide
These instructions must be left with the user
1
For SPARES,
ADVICE or REPAIRS
please call us free
on 0800 001 4040
(UK only)
1493623-W2-A

Advertisement

Table of Contents
loading

Summary of Contents for Kohler Mira Sport J03A

  • Page 1 Mira Sport 7.5, 9.0, 9.8 and 10.8 kW For SPARES, ADVICE or REPAIRS please call us free on 0800 001 4040 (UK only) Installation and User Guide These instructions must be left with the user 1493623-W2-A...
  • Page 2: Important Safety Information

    Important Safety Information WARNING - This shower can deliver scalding temperatures, cause fire, electric shock or other personal injury if not operated, or maintained in accordance with the instructions, warnings and cautions contained in this guide and on the appliance. Please read the important safety information and the operation section of this guide before using the shower.
  • Page 3 9. Installation of the shower must be carried out in accordance with these instructions by qualified, competent personnel. Read all instructions before installing the shower. 10. DO NOT switch the shower on if water starts leaking from the shower case. Isolate the electrical supply to the shower immediately. 11.
  • Page 4 Only Kohler Mira recommended accessories should be used. 23. DO NOT perform any unspecified modifications, or drill or cut holes in the product other than instructed by this guide.
  • Page 5: Pack Contents

    Pack Contents Tick the appropriate boxes to familiarize yourself with the part names and to confirm that the parts are included. 1 x Electric Shower  2 x Case Inserts  1 x Olive   1 x Compression Nut Documentation  1 x Installation Guide and User Guide  1 x Installation Template  1 x Guarantee Brochure 1493623-W2-A...
  • Page 6: Wiring Diagram

    Wiring Diagram BROWN B BLUE C BLUE E GREEN D Heater Tank RED K BROWN F BROWN J Terminal RED H Block GREEN A GREEN A GREEN D BROWN G Push Button Micro Micro Switch Switch (R) Switch (L) Inlet Connector Solenoid BLACK M BLACK L...
  • Page 7: Products Covered

    Products manufactured by Kohler Mira Ltd are designed to be safe provided, that they are installed used and maintained in good working order, in accordance with our instructions and recommendations.
  • Page 8: Specifications

    Specifications Plumbing Variant 10.8 Minimum Dynamic Pressure 70 kPa (0.7 70 kPa (0.7 70 kPa (0.7 100 kPa (1.0 bar) bar) bar) bar) Maximum Dynamic Pressure* 500 kPa (5.0 bar) Maximum Static Pressure* 1000 kPa (10 bar) Minimum Static Pressure 20 kPa (0.2 bar) Maximum Inlet Temperature 30°C...
  • Page 9: Disposal And Recycling

    Guarantee This product has been designed for domestic use only, Mira Showers guarantee this product against any defect in materials or workmanship for a period of two years from the date of purchase (shower fittings for one year). For terms and conditions, refer to the back cover of this guide. European Conformity Information This range of electric showers complies with the following European directives: 2014/35/EU - Low Voltage Directive (LVD),...
  • Page 10: Installation Requirements

    Installation Requirements Plumbing 1. The plumbing installation must comply with all national or local water regulations and all relevant building regulations, or any particular regulation or practice specified by the local water supply company. 2. DO NOT use sealing compounds on any pipe fitting or joints. 3.
  • Page 11 17. A water treatment device should be installed where the water hardness may exceed 200 ppm. Malfunctions caused by excessive limescale formation are not covered by this shower’s guarantee (see back page for details). 18. The installation must not cause the hose to be sharply kinked during normal use.
  • Page 12 Electrical 1. The electrical installation must comply with BS 7671 (commonly referred to as the IEE Wiring Regulations) and all relevant building regulations, or any particular regulation or practice specified by the local electricity supply company. 2. Ensure that all circuit protection devices, switches and cabling is adequate for the rated current of the shower and that the rating of the electricity supply company fuse and the consumer unit are adequate for the additional demand.
  • Page 13: Installation

    Installation Warning! Turn off the electrical and water supplies before proceeding with the installation of the shower. Remove the three screws that hold the cover on and remove the Screws cover. Remove the service tunnel. Using the installation template supplied, mark the positions of the three fixing holes.
  • Page 14 Connect the inlet supply pipe to the inlet connector using the compression nut and olive (supplied). Inlet Always provide mechanical support when making plumbing Connector connections. Olive Upon completion of the installation ensure connections and back Compression case are not under any stress due to misaligned pipework or electrical cables.
  • Page 15 Do not use alternative screws to secure the cover. This can cause internal damage to the appliance. Do not seal around the back of appliance. HIGH This completes the installation, follow the guidelines in section 'COMMISSIONING' to prepare the shower POWER for use.
  • Page 16 Commissioning Before carrying out the commissioning procedure install the Shower Fittings, refer to the Shower Fittings Installation and User Guide. If you are unsure how an electric shower works, please read through the section “User Instructions” before continuing. HIGH Switch on the electrical supply. POWER TEMPERATURE Turn temperature control to the...
  • Page 17 HIGH COLD HIGH 5 - 10 secs POWER COLD Turn power control to Eco. POWER 5 - 10 secs Temperature will rise slightly. Turn power control to High. COLD 5 - 10 secs TEMPERATURE COLD 10 secs Temperature will rise further. Adjust temperature as required.
  • Page 18: Operation

    Operation Read the section “Important Safety Information” first. Push the START/STOP button to turn ON the appliance. Light in the button illuminates. Switch on the electrical supply. HIGH POWER POWER Turn the power control to the desired position. TEMPERATURE TEMPERATURE Adjust the temperature as required.
  • Page 19 A small amount of water may continue to drain over a few minutes. Warning! Turning the shower off and back on during showering may result in unstable temperatures at the showerhead. Always ensure the temperature has stabilised before re-using the shower. Note: A slight hissing sound may be heard from the shower during operation.
  • Page 20 The Effect of Other Water Devices Example of how shower temperature stabilises due to pressure changes. HIGH Selected Showering POWER Temperature TEMPERATURE Showering temperature will stabilise to within 6°C band if other outlets are opened whilst showering, providing the minimum pressure does not fall below 70 kPa (0.7 bar).
  • Page 21: Fault Diagnosis

    Fault Diagnosis Warning! There are no user serviceable components beneath the cover of the appliance. In the event of a malfunction of the shower, the troubleshooting information below provides details on possible causes and remedies that may be carried out by qualified, competent personnel.
  • Page 22 Symptom Start/Stop Power Control Possible Cause Possible Light is ON Position Remedy or OFF (Continued) Flow valve faulty. Replace flow valve. Replace heater tank. In hard water Heater tank excessively areas consider the use of a water scaled. softener. Remove and descale Showerhead blocked.
  • Page 23 Cleaning Always read the IMPORTANT SAFETY INFORMATION for your shower. Cleaning the showerhead Many household and commercial cleaners, including hand and surface cleaning wipes contain abrasive and chemical substances that can damage plastics, plating and printing and should not be used. These finishes should be cleaned with a mild washing up detergent or soap solution, and then wiped dry using a soft cloth.
  • Page 24 Servicing Warning! There are no user serviceable parts inside the shower. Servicing of the shower must only be carried out by qualified, competent personnel following the instructions provided in this guide and those provided with any spare part. Before replacing any parts, ensure that the underlying cause of the malfunction has been resolved.
  • Page 25: Spare Parts

    Spare Parts 1746.436 Thermal Switch 1746.438 (7.5kW) 1746.439 (9.0kW) 1746.440 (9.8kW) 1746.441 (10.8kW) 1746.449 Heater Tank Terminal (includes Block microswitches) 1746.442 * 1746.443 * Flow Valve 1746.444 Switch 1829.062 Assembly Inlet Filter 1746.447 Outlet 1746.435 Connector Inlet Clamp 1746.446 1746.434 Switch / LED Inlet Assembly...
  • Page 26 Notes 1493623-W2-A...
  • Page 27 Notes 1493623-W2-A...
  • Page 28: Customer Support

    Kohler Mira Limited. Cromwell Road, K/E S.A.S. Cheltenham, 3 rue de Brennus, The company reserves the right Gloucestershire 93631, La Plaine Saint-Denis, to alter product specifi cations GL52 5EP France without notice. 14648 1473739-W6-A 1493623-W2-A © Kohler Mira Limited, August 2021...

This manual is also suitable for: