Mira Sport Thermostatic 9.0 & 9.8 kW For SPARES, ADVICE or REPAIRS Please call us on 0844 571 5000 (UK Only) These instructions must be left with the user Installation Guide...
Page 2
Products manufactured by Kohler Mira Ltd are designed to be safe provided, that they are installed used and maintained in good working order, in accordance with our instructions and recommendations.
DO NOT perform any unspecified modifications to the shower or its accessories. When servicing only use genuine Kohler Mira replacement parts. 10. If the shower is dismantled during installation or servicing then upon completion the product must be inspected to ensure all electrical connections are tight and that there are no leaks.
PACK CONTENTS Tick the appropriate boxes to familiarise yourself with the part names and to confirm that the parts are included. 1 x Mira Sport Thermostatic Electric Shower 1 x Olive 1 x Compression Nut 3 x Fixing Screws ...
WIRING DIAGRAM BROWN B BLUE C BLUE E GREEN D HEATER TANK RED K BROWN F BROWN J TERMINAL RED H BLOCK GREEN A GREEN A GREEN D BROWN G MICRO MICRO PUSH BUTTON SWITCH (L) SWITCH (R) SWITCH INLET CONNECTOR SOLENOID BLACK M...
INSTALLATION REQUIREMENTS Please read the Important Safety Information and specifications sections at the front of this guide, and the requirements detailed in this section before installing the shower. WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY: Plumbing The plumbing installation must comply with all national or local water regulations and all relevant building regulations, or any particular regulation or practice...
Page 8
15. A full bore/non restrictive servicing valve must be fitted in a readily accessible position adjacent to the shower to facilitate maintenance of the shower. DO NOT use a valve with a loose washer plate (jumper) as this can lead to a build up of static pressure.
Page 9
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY: Electrical The electrical installation must comply with BS 7671 (commonly referred to as the IEE Wiring Regulations) and all relevant building regulations, or any particular regulation or practice specified by the local electricity supply company. Ensure that all circuit protection devices, switches and cabling is adequate for the rated current of the shower and that the rating of the electricity supply company fuse and the consumer unit are adequate for the additional demand.
INSTALLATION Warning! Isolate the electrical and water supplies before installing the shower. Remove the three screws that Screws hold the cover on and remove Service the cover. Tunnel Remove the service tunnel. Using the installation template supplied, mark the positions of the three fixing holes.
Page 11
Determine the direction and route of the incoming water supply: falling (entering the shower from the top), or rising (entering the shower from the bottom). NOTE! - DO NOT use an incoming supply entering the shower directly from the back. Add an elbow to the supply pipe and connect it as a rising or falling supply.
Page 12
Connect the inlet supply pipe to the inlet connector using Inlet the compression nut and olive Connector (supplied). Always provide mechanical support when making plumbing connections. Upon Olive completion of the installation ensure connections and back Compression case are not under any stress due to misaligned pipework or Inlet Supply electrical cables.
Page 13
E n s u r e t h e e a r t h b o n d i n g Screws c o m p l i e s w i t h r e l e v a n t regulations.
Page 14
COMMISSIONING HIGH POWER TEMPERATURE Turn temperature control to Turn power control to low. Switch on the electrical supply. the cold position. HIGH COLD 0 - 15 secs Water flows freely within a POWER Push START/STOP button. Turn power control to Eco. few seconds, temperature Light in the button illuminates.
FAULT DIAGNOSIS In the event of a malfunction of the shower, the troubleshooting information below provides details on possible causes and remedies that may be carried out by qualified, competent personnel. Non-qualified personnel should refer to the fault diagnosis section in the users guide. WARNING There are no user serviceable components beneath the cover of the shower.
Page 16
Start/Stop Power Symptom Light is Control Possible Cause Possible Remedy ON or OFF Position Insufficient water supply Showerhead Minimum static pressure dripping. pressure for shut off. to ensure shut off and prevent dripping is 20 kPa (0.2 bar). Note! If other appliances are operating, static pressure may drop below 20 kPa (0.2 bar).
Page 17
Start/Stop Power Symptom Light is Control Possible Cause Possible Remedy ON or OFF Position Microswitch failure. Replace microswitch. change in Insufficient mains water Contact local water temperature pressure. company. between Low / Eco / Possible failure of flow Use a suitable device to High setting.
Page 18
SERVICING WARNING There are no user serviceable parts inside the shower. Servicing of the shower must only be carried out by qualified, competent personnel following the instructions provided in this guide and those provided with any spare part. Before replacing any parts, ensure that the underlying cause of the malfunction has been resolved.
Page 21
Check out our full range of Showers Electric Showers Digital Showers Mixer Showers Power Showers Smart Showers Shower Towers From Top Shower Brands Mira Showers Aqualisa Showers Triton Showers Gainsborough Showers Shower Pumps can upgrade your showering experience even more Stuart Turner Shower Pumps Salamander Shower Pumps Grundfos Shower Pumps...