Kohler Mira Sport Thermostatic 9.0 kW Installation Manual
Hide thumbs Also See for Mira Sport Thermostatic 9.0 kW:

Advertisement

Quick Links

Mira Sport Thermostatic
9.0 & 9.8 kW
For SPARES, ADVICE
or REPAIRS
Please call us on
0844 571 5000
(UK Only)
These instructions must be left with the user
Installation Guide
1

Advertisement

Table of Contents
loading

Summary of Contents for Kohler Mira Sport Thermostatic 9.0 kW

  • Page 1 Mira Sport Thermostatic 9.0 & 9.8 kW For SPARES, ADVICE or REPAIRS Please call us on 0844 571 5000 (UK Only) These instructions must be left with the user Installation Guide...
  • Page 2 Products manufactured by Kohler Mira Ltd are designed to be safe provided, that they are installed used and maintained in good working order, in accordance with our instructions and recommendations.
  • Page 3: Important Safety Information

    DO NOT perform any unspecified modifications to the shower or its accessories. When servicing only use genuine Kohler Mira replacement parts. 10. If the shower is dismantled during installation or servicing then upon completion the product must be inspected to ensure all electrical connections are tight and that there are no leaks.
  • Page 4: Pack Contents

    PACK CONTENTS   Tick the appropriate boxes to familiarise yourself with the part names and to confirm that the parts are included. 1 x Mira Sport Thermostatic Electric Shower   1 x Olive   1 x Compression Nut   3 x Fixing Screws  ...
  • Page 5: Wiring Diagram

    WIRING DIAGRAM BROWN B BLUE C BLUE E GREEN D HEATER TANK RED K BROWN F BROWN J TERMINAL RED H BLOCK GREEN A GREEN A GREEN D BROWN G MICRO MICRO PUSH BUTTON SWITCH (L) SWITCH (R) SWITCH INLET CONNECTOR SOLENOID BLACK M...
  • Page 6: Specifications

    SPECIFICATIONS Thermostatic Variant Plumbing Sport 9.0 Sport 9.8 Minimum Dynamic Pressure 70 kPa (0.7 bar) Maximum Dynamic Pressure * 500 kPa (5 bar) 20 kPa (0.2 bar) Minimum Static Pressure Maximum Static Pressure * 1000 kPa (10 bar) Maximum Inlet Temperature 30°C Minimum Inlet Temperature 2°C...
  • Page 7: Installation Requirements

    INSTALLATION REQUIREMENTS Please read the Important Safety Information and specifications sections at the front of this guide, and the requirements detailed in this section before installing the shower. WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY: Plumbing The plumbing installation must comply with all national or local water regulations and all relevant building regulations, or any particular regulation or practice...
  • Page 8 15. A full bore/non restrictive servicing valve must be fitted in a readily accessible position adjacent to the shower to facilitate maintenance of the shower. DO NOT use a valve with a loose washer plate (jumper) as this can lead to a build up of static pressure.
  • Page 9 WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY: Electrical The electrical installation must comply with BS 7671 (commonly referred to as the IEE Wiring Regulations) and all relevant building regulations, or any particular regulation or practice specified by the local electricity supply company. Ensure that all circuit protection devices, switches and cabling is adequate for the rated current of the shower and that the rating of the electricity supply company fuse and the consumer unit are adequate for the additional demand.
  • Page 10: Installation

    INSTALLATION Warning! Isolate the electrical and water supplies before installing the shower. Remove the three screws that Screws hold the cover on and remove Service the cover. Tunnel Remove the service tunnel. Using the installation template supplied, mark the positions of the three fixing holes.
  • Page 11 Determine the direction and route of the incoming water supply: falling (entering the shower from the top), or rising (entering the shower from the bottom). NOTE! - DO NOT use an incoming supply entering the shower directly from the back. Add an elbow to the supply pipe and connect it as a rising or falling supply.
  • Page 12 Connect the inlet supply pipe to the inlet connector using Inlet the compression nut and olive Connector (supplied). Always provide mechanical support when making plumbing connections. Upon Olive completion of the installation ensure connections and back Compression case are not under any stress due to misaligned pipework or Inlet Supply electrical cables.
  • Page 13 E n s u r e t h e e a r t h b o n d i n g Screws c o m p l i e s w i t h r e l e v a n t regulations.
  • Page 14 COMMISSIONING HIGH POWER TEMPERATURE Turn temperature control to Turn power control to low. Switch on the electrical supply. the cold position. HIGH COLD 0 - 15 secs Water flows freely within a POWER Push START/STOP button. Turn power control to Eco. few seconds, temperature Light in the button illuminates.
  • Page 15: Fault Diagnosis

    FAULT DIAGNOSIS In the event of a malfunction of the shower, the troubleshooting information below provides details on possible causes and remedies that may be carried out by qualified, competent personnel. Non-qualified personnel should refer to the fault diagnosis section in the users guide. WARNING There are no user serviceable components beneath the cover of the shower.
  • Page 16 Start/Stop Power Symptom Light is Control Possible Cause Possible Remedy ON or OFF Position Insufficient water supply Showerhead Minimum static pressure dripping. pressure for shut off. to ensure shut off and prevent dripping is 20 kPa (0.2 bar). Note! If other appliances are operating, static pressure may drop below 20 kPa (0.2 bar).
  • Page 17 Start/Stop Power Symptom Light is Control Possible Cause Possible Remedy ON or OFF Position Microswitch failure. Replace microswitch. change in Insufficient mains water Contact local water temperature pressure. company. between Low / Eco / Possible failure of flow Use a suitable device to High setting.
  • Page 18 SERVICING WARNING There are no user serviceable parts inside the shower. Servicing of the shower must only be carried out by qualified, competent personnel following the instructions provided in this guide and those provided with any spare part. Before replacing any parts, ensure that the underlying cause of the malfunction has been resolved.
  • Page 19: Spare Parts

    SPARE PARTS 1563.719 Thermal Switch 1746.449 Terminal Block 872.01 1746.458 (9.0kW) Microswitch 1746.459 (9.8kW) (2 pin) Heater Tank 1746.444 Switch 1563.536 Assembly Control Belt 1563.540 1829.062 Inlet Valve Inlet Filter 1563.538 1829.063 Temp Cam Inlet & Pulley Connector 416.38 Inlet Clamp 416.51 Coil 1746.461...
  • Page 20 (excludes Eire). Ring 01922 471763 for more details. Mira is a registered trade mark of Kohler Mira Limited. The company reserves the right to alter product specifi cations without notice. FM 14648 © Kohler Mira Limited, July 2013 1175284-W2-C...
  • Page 21 Check out our full range of Showers Electric Showers Digital Showers Mixer Showers Power Showers Smart Showers Shower Towers From Top Shower Brands Mira Showers Aqualisa Showers Triton Showers Gainsborough Showers Shower Pumps can upgrade your showering experience even more Stuart Turner Shower Pumps Salamander Shower Pumps Grundfos Shower Pumps...