Download Print this page

Whirlpool UI MISTRAL Manual page 73

For i200 – i270

Advertisement

Operation
Power management – Mistral (I200 and I270)
Once the appliance is connected to the main power, the power level can be set within
60 seconds after the hob is plugged in. To access the power management, it needs to
be pressed and hold for 5 seconds the (+) button of timer (the one on the right side, if
2 timers are available) after the config code is shown. The display will show "PL".
Once the power limitation menu is active, press again "CL", to access the settings.
Through the (+) and (-) button of right timer is possible to scroll settings. To choice
the preferred one it needs to press CL button to confirm
WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati

Advertisement

loading