Troubleshooting
Failure description / repair Mistral I270
Code shown
Failure description
on display
F-00
acoustic signal
F-FF
F-12
Coil under current
F-21
main frequency wrong
F-25
Fan Stuck on IPC #
WHIRLPOOL CORPORATION ▪ CONFIDENTIAL ▪ EMEA CS&Quality Technical Training and Serviceability Team ▪ By Nicola Padula and Nicola Bargagnati
Type of
Points to check subsequently until the appliance starts to work properly again.
failure
Type 3 One or more keys are pressed permanently for more than 10 sec. (USIF side). The cause
could be liquid, dirty, or objects on the glass, near or on the keys. In this case the USIF will
switch OFF the cooktop, setting all level set to zero, but no Failure will be shown
Type 1 1)
Check if the coil, that is showing the failure, is well plugged in the proper connector.
2)
Replace the coil with a new one (coil of the same size). If this does not fix the hob, then
the old coil is still good, place it back in the appliance.
3)
Change the IPC to which the coil is connected
Type 2 1)
Check the frequency of the phase connected to the IPC. If the frequency is not
(50Hz) the cause of the failure is not due to the appliance.
2)
If the frequency is OK change the IPC showing the failure.
Check Fan connection – if the connector is plugged in well or not.
Type 2 1)
2)
Replace the Fan with a new one.
3)
If replacing the fan with a new one did not fix the appliance, then the old fan is still
good. Put it back in the appliance. Change the IPC showing the failure.