Page 1
Mover SE Mover TE Version UK Operating instructions Page 3 Installation instructions Page 7 To be kept in the vehicle! Sales and Service in UK and Eire: Truma (UK) Limited Foston telephone: (01283) 58 60 20 sales@trumauk.com 2000 Park Lane, Dove Valley Park...
General instructions l Practice operating the Mover in an open area before using The Mover SE was developed for overcoming inclines of up to for the first time. This to fully familiarise yourself with approx. 25% with a gross weight of 1200 kg and 15% with a the handset/mover operation.
The remote hand set switches off: Please note that the Mover SE is only suitable for single- axle towed vehicles, and the Mover TE is only suitable after approx. 2 minutes, if no button is pressed for twin-axle towed vehicles.
With the Mover SE, the „left forward” (e) and „right reverse” (f) Charge the caravan battery before starting up. or „right forward” (d) and „left reverse” (g) buttons can also be...
OK. If the fuse is defective, check the swivel-in motor connect- ing cables at the controller for possible short circuiting! – as a result of not original Truma parts being used in the appliance 5. Perform a reset – approx. 10 seconds – (briefly disconnect the battery, move isolating switch to „OFF”...
Page 7
L-Profile Intended use Measuring the chassis height The Mover SE is designed for use on single-axle caravans with a gross weight of up to 1800 kg, Frame height (Y) measured at distance of 106 mm (X) from the and the Mover TE is designed for use on dual-axle caravans outer edge of the tyre at height of hub/middle of tyre.
Detailed installation instructions are provided with the relevant mounting set. M 8 x 60 (4 x) The Mover SE/TE is not approved for installation on Washer 8 caravans/trailers with any other chassis! (8 x) Any drilling (exception: when using flat frame kit) or welding to the chassis is not allowed.
Driving direction min. 110 mm gearbox. Truma can supply a spacer plate set for compensating for height differences of up to 45 mm (Part no. 60010-66000, 2 pcs. à 15 mm). Up to three spacer plates can be used at each side.
Page 10
Connecting diagram leadthrough grommets for protection in order to prevent damage to cables. Installation in front of Installing the isolating switch Fuse Swivel-in Safety Drive Drive axle Battery motors contact motor motor Install isolating switch in a suitable location (near the battery) –...
Loosely route cable through strain relief (k) and secure with 13-pin safety socket: 2 sheet metal screws. Depending on the installation situation, the cable can be led out of the socket holder through one of Connect pin 11 of the caravan plug to the negative battery the three recesses.
LV, MT, NL, NO, PL, PT, SE, SI, SK Supplementary information: class 1, Frequency 434 MHz (Mover S) class 1, Frequency 868 MHz (Mover SE and TE) Place and date of issue: Putzbrunn, 31.03.2006 Signed by or for the manufacturer:...
Page 14
✂ Warranty Card Garantie-Karte Bon de Garantie Certificato di Garanzia Garantiebon Garantikort Tarjeta de garantía ✂...
Page 15
Door de dealer in te vullen. Vom Händler auszufüllen Udfyldes af forhandleren. A remplir par le commerçant A ser rellendada por el commerciente. Da far compilare dal rivenditore ✂ Mover SE/TE Date of sale Verkaufsdatum Date de vente Warranty Card Version UK Data di vendita...
Need help?
Do you have a question about the Mover SE and is the answer not in the manual?
Questions and answers