Installation; Place Ram In Basic Position - Gechter 20 KHKP Operation Manual

Pneumatic toggle presses with adjustable guide unit
Table of Contents

Advertisement

6

Installation

RISKS OF INJURY
due to maloperation!
Installing of the press and setting of the tool may only be carried out by
WARNING!
skilled personnel with the relevant technical qualification and expertise..
During maintenance and servicing with switched off air supply the ram can
fall. Therefore, before start of work an appropriate support has to be inserted
into the tool which will be able to carry the maximum press force of the press.
Because the tool will be designed by the customer it is not possible for the
manufacturer to provide a fixture.
The door at the front of the guide unit (→ Fig1, (4)) must always remain
closed when operating the press!
Before opening the control box always switch off the main switch and
disconnect the device from the electric current (disconnect mains plug)!
When working on the press, e.g. tool change, the press must be
disconnected from the compressed air supply if possible (using manual slide
valve, → page 25, Pneumatic connection of press).
The following tools are required for installation of the press:
Tools
Box wrench
Torque wrench
Flat wrench
Hexagon socket
wrench
Key for door of
guide unit
Tools for installation of the press
Tab. 7
6.1

Place ram in basic position

Follow instructions of section "Setting operation" in the Operation Manual of
the press control.
Ram of press will then be in top basic position.
Version 1.6
GECHTER
– Pneumatic toggle presses
20 kN KHKP
SW 19
SW 19
tightening torque 90 Nm
SW 17, SW 22
sizes 4 and 5
– 29 / 49 –
20 kN KHKP, 60 kN KHKP
60 kN KHKP
SW 24
SW 24
tightening torque 170 Nm
SW 30, SW 36
sizes 4 and 6
included