Pneumatic Connection Of Press - Gechter 20 KHKP Operation Manual

Pneumatic toggle presses with adjustable guide unit
Table of Contents

Advertisement

5.4

Pneumatic connection of press

According to EN 13736 a service unit for pneumatic presses is mandatory. For
this reason
service unit.
The pneumatic connection will be carried out on the manual slide valve of the
service unit.
When setting the service unit please follow the relevant descriptions in the
separate Operation Manual of the service unit.
NOTE
Depending on the type of press the feed hose should be dimensioned as follows:
Overall size
Inner width of the
connecting hose
Dimensioning of feed hose
Tab. 5
Push the feed hose over the hose
fitting on the manual slide valve of
the service unit (Fig. 4).
Fasten feed hose with the hose
binder.
Move manual slide valve in
forward direction (P → A)
(Fig. 5).
Version 1.6
GECHTER
GECHTER
- presses will always be delivered with the appropriate
20 kN KHKP
Ø 9 mm (equiv. ¼")
– 25 / 49 –
– Pneumatic toggle presses
20 kN KHKP, 60 kN KHKP
Fig. 4 Hose fitting on the manual slide
valve of the service unit
(1)
A
Fig. 5 Manual slide valve in forward direction
Pos. 1 Junction side of service unit
Pos. 2 Junction side of air grid
60 kN KHKP
Ø 12 mm (equiv. ½")
(2)
P
08/2009