Broan SmartSense
R EA D AND SAVE TH E SE I N ST R U CT I O NS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address or
telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. This unit must be grounded.
7. Do not connect this product as a load on a fan speed control or
light dimmer.
8. Read and understand entire instructions before proceeding with
installation.
WARRANTY
BROAN-NUTONE ONE YEAR LIMITED WARRANTY
Broan-NuTone warrants to the original consumer purchaser of its products that such products
will be free from defects in materials or workmanship for a period of one year from the date of
original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT
NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE.
During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge,
any product or part which is found to be defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, TUBES, AND FUSES.
This warranty does not cover (a) normal maintenance and service or (b) any products or parts
which have been subject to misuse, negligence, accident, improper maintenance or repair
(other than by Broan-NuTone), faulty installation or installation contrary to recommended
installation instructions.
The duration of an implied warranty is limited to the one-year period as specified for the
express warranty. Some states do not allow limitation on how long an implied warranty lasts,
so the above limitation may not apply to you.
BROAN-NUTONE'S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE'S OPTION, SHALL
BE THE PURCHASER'S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE
SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT
OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the
exclusion or limitation of incidental or consequential damages, so the above limitation may
not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary
from state to state. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone at the address or telephone
number below, (b) give the model number and part identification and (c) describe the nature of
any defect in the product or part. At the time of requesting warranty service, you must present
evidence of the original purchase date.
Broan-NuTone LLC Hartford, Wisconsin www.broan.com 800-558-1711
Intelligent Ventilation System
®
INSTALLATION
Install controls and wire them as shown. Use following guidelines:
• IMPORTANT:
QTXE080 Ultra Silent™ fan must be wired to SMSC080
QTXE110 Ultra Silent™ fan must be wired to SMSC110
• Use minimum 75 °C rated electrical wiring.
• Except for required neutral wire, these controls install like
• Specify deep device electrical boxes where controls will be
• All controls must be grounded using attached ground wire.
MODELS SSQTXE080 • SSQTXE110
LINE
Black
GROUND
POWER
Bare
LINE
Copper
(GFCI
protected
if required)
NEUTRAL
White
SmartSense
control.
®
SmartSense
control.
®
normal switches. Make sure electrician knows each control
location must have a neutral wire. Neutral wire at switch
locations may be code requirement or regular practice in
installation municipality; but unless explicitly specified,
electrician might not install it.
installed. These controls fit in most North American electrical
boxes; however, deep boxes provide extra working space which
eases installation. Labor cost savings can offset higher box
costs, which is usually less than a dollar over standard depth
boxes. Use boxes that have 18 cu. in. minimum volume and
are at least 1-1/2 in. deep.
Page 1
LINE
Black
MASTER
GROUND
or SLAVE
Bare
CONTROL
Copper
LOAD
Red
NEUTRAL
White
WHITE
BLACK
GROUND
Green
FAN

Advertisement

loading
Need help?

Need help?

Do you have a question about the SSQTXE080 and is the answer not in the manual?

Questions and answers

Summary of Contents for Broan SSQTXE080

  • Page 1 This warranty supersedes all prior warranties. To qualify for warranty service, you must (a) notify Broan-NuTone at the address or telephone number below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part.
  • Page 2: Control Operation

    “How To Set System Level” section. One Broan SmartSense set up. Any control can be selected as system Master, but typically master bathroom control is chosen. All controls are factory set as system Masters; therefore, installations will operate as independent systems at factory set system level after installation if following set up is not done. One Master control can link up to 10 Broan SmartSense LinkLogic™ devices. SmartSense Master control are called Slaves. HOW TO LINK SMARTSENSE 1. Unless another control is designated and clearly marked on frame, under decorative plate, or documented on this instruction sheet as Master control, go to master bathroom control. 2. Put Master control in Program mode; press and hold SET button for 3-seconds and then release it.
  • Page 3: Feature Selections

    (slow-blink). Automatic-Off/Delayed-Off Feature Selection mode entry is accomplished using same method with Off paddle. Once either Feature Selection mode is entered, pressing and holding associated paddle displays Feature’s status using LED. Press and release associated paddle to toggle feature on or off. When finished, press and release SET button to exit Feature MODELS SSQTXE080 • SSQTXE110 TABLE A Bedrooms Floor Area (ft 0 - 1 2 - 3 <...
  • Page 4 4. F or option (1a), turn circuit breaker on while SET button is pressed. For option (1b), push in and press SET button in one motion. 5. C ontinue holding SET button for 3-seconds after power is applied then release it. , LINKLOGIC™, AND ® W ithin 2-seconds, fan and LED turn on; stay on for 1 to 2-seconds and then turn off. 6. I f control does not respond as described, start process over with step 1. SCREWS MODELS SSQTXE080 • SSQTXE110 Page 4 System” procedure. ® PADDLE / FRAME ASSEMBLY Push to turn ON ® SCREWS mart ense ®...
  • Page 5: Instalación

    Esta garantía sustituye todas las garantías anteriores. Para tener derecho al servicio de la garantía, usted debe (a) notificar a Broan NuTone a la dirección y número de teléfono que aparecen abajo, (b) proporcionar el número de modelo y la identificación de la pieza y (c) describir la naturaleza de cualquier defecto en el producto o pieza.
  • Page 6 Las instalaciones múltiples se enlazan y comunican a través de los circuitos eléctricos normales de la vivienda, para formar una red de calidad respecto al aire interior. En instalaciones múltiples típicas, el control maestro se localiza en el baño principal. Las campanas habilitadas por Broan y Best de Broan LinkLogic™ y los reguladores eléctricos habilitados por LinkLogic™ se pueden vincular con el SmartSense tal manera que se incluya su contribución con la ventilación de calidad del aire interior.
  • Page 7 12. Si son iguales, entonces el nivel de sistema se configuró correctamente; de otra manera, reajuste el nivel de sistema comenzando desde el paso 5. SELECCIONES DE FUNCIONES Modo de vacaciones: Se utiliza solamente con el control maestro. Inhabilita temporalmente el sistema SmartSense de Broan. El control maestro no ® enciende automáticamente su ventilador o cualquier otro ventilador del sistema. Después de salir del modo de selección de función, el modo de vacaciones se cancela cuando se presiona la paleta ON del control maestro. Modo de desactivación: Excluye al ventilador del uso de ventilación automática. No afecta la operación manual y su ventilación se acredita para...
  • Page 8 4. En otro control, presione y sostenga el botón SET. 5. Continúe sosteniendo el botón SET durante 3 segundos y luego suéltelo. En menos de 2 segundos, el ventilador y el LED se encienden, se mantienen encendidos de 1 a 2 segundos y luego se apagan. 6. Si el control no responde tal como se describió, repita el proceso a partir del paso 1. CÓMO CAMBIAR EL COLOR DEL CONTROL Se incluye un conjunto de paleta/bastidor color almendra. MODELOS SSQTXE080 • SSQTXE110 1. Utilice un desarmador Phillips N. 1 magnético y retire los cuatro (4) tornillos de la paleta/bastidor color blanco. 2. Quite la paleta/bastidor color blanco del control. Precaución: No toque ni ponga nada dentro de la caja del control; puede dañarse el control. 3. Coloque la paleta/bastidor color almendra sobre el control. 4. Reemplace los cuatro (4) tornillos y apriételos ligeramente.

This manual is also suitable for:

Smartsense ssqtxe110Smartsense ssqtxe080