Electrical Box
Step
7
Disconnect the relay
connector for the
compressor.
8
Remove the screw of
the stop valve cover.
9
Slide the stop valve
cover downward and
remove it.
10 Remove the 3 screws.
8
Procedure
Relay connector for compressor
Stop valve cover
Points
(R26017)
When reassembling, make
sure that the 4 hooks are
securely fastened.
(R26018)
(R26020)
Removal Procedure
Si002154E
Hook
Hook
(R26019)