IR 2005 SC / IRS 2005
EN
OPERATING MANUAL
RADIANT HEATER

Advertisement

Table of Contents
loading

Summary of Contents for Trotec IR2005 SC

  • Page 1 IR 2005 SC / IRS 2005 OPERATING MANUAL RADIANT HEATER...
  • Page 2: Table Of Contents

    EU declaration of conformity via the following link: Notes regarding the operating manual......... 2 Safety .................. 2 Information about the device.......... 5 IR 2005 SC Transport and storage............ 6 Assembly and start-up............ 7 https://hub.trotec.com/?id=45786 Operation ................ 10 Errors and faults.............. 11 Maintenance ................ 12 IRS 2005 Technical annex.............. 13 Disposal ................ 13 https://hub.trotec.com/?id=45787...
  • Page 3 Maintenance tasks which require the housing to be opened device's radiator side and all combustible materials such must only be carried out by specialist electrical companies or by as textiles, curtains, beds and sofas. Trotec. radiant heater IR 2005 SC / IRS 2005...
  • Page 4 Safety signs and labels on the device The following label is attached to the device in English. Note Do not remove any safety signs, stickers or labels from the device. Keep all safety signs, stickers and labels in legible condition. The following safety signs and labels are attached to the device: Symbols Meaning...
  • Page 5: Information About The Device

    Warning Information about the device In order to avoid overheating and fire hazards, the device must not be covered! Device description devices IR 2005 SC IRS 2005 are used to quickly Warning generate instant heat. Coarse dirt particles on the heating rods can cause the device IR 2005 SC is a parasol heater.
  • Page 6: Transport And Storage

    Device depiction Transport and storage IR 2005 SC Note If you store or transport the device improperly, the device may be damaged. Note the information regarding transport and storage of the device. Transport Before transporting the device, observe the following: •...
  • Page 7: Assembly And Start-Up

    Assembly Assembly and start-up Warning Scope of delivery Risk of fire due to improper installation! IR 2005 SC There is a risk of fire if the required minimum • 1 x device distances are not observed. Observe the “Installation” section in the “Assembly and •...
  • Page 8 4. Fold the heating blades into a horizontal position until they 4. Fit the radiant heater on the telescopic rod. ð The three heating blades point downwards. engage with a click. ð Hold on to the radiant heater, as otherwise it will slip. If necessary, seek assistance from a second person.
  • Page 9 Retracting the heating blades of the IR 2005 SC and Installation IRS 2005 When installing the device, observe the minimum distances from walls and other objects as described in the Technical data Warning of hot surface chapter. The protective grid (1) heats up during operation and can still be hot after switch-off.
  • Page 10: Operation

    Start-up Operation Info Operating elements Odours might arise upon initial start-up or after a longer period of non-use. • Before restarting the device, check the condition of the power cable. If there are doubts as to the sound condition, contact the customer service. •...
  • Page 11: Errors And Faults

    • Allow the device to cool down completely. device is not starting, have the electrics checked by a • Hold onto the mains plug while pulling the power cable out specialist company or by Trotec. of the mains socket. The device does not emit heat: •...
  • Page 12: Maintenance

    • Allow the device to cool down completely. Warning of electrical voltage Tasks which require the device to be opened must only be carried out by authorised specialist companies or by Trotec. Cleaning the device Warning of electrical voltage Never immerse the device in water!
  • Page 13: Technical Annex

    You can also find out about other return options that apply for many EU countries on the website https://hub.trotec.com/?id=45090. Otherwise, please contact an official recycling centre for electronic and electrical equipment authorised for your country.
  • Page 14 Trotec GmbH Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.com...

This manual is also suitable for:

Irs2005

Table of Contents