Summary of Contents for Trotec IRS 2000 E

  • Page 1 IRS 2000 E OPERATING MANUAL RADIANT HEATER...
  • Page 2: Table Of Contents

    (e.g. material damage), but does not indicate hazards. Info Information marked with this symbol helps you to carry out your tasks quickly and safely. Follow the manual Information marked with this symbol indicates that the operating manual must be observed. radiant heater IRS 2000 E...
  • Page 3: Safety

    • Do not sit on the device. positioned incorrectly. • This appliance is not a toy! Keep away from children and animals. Do not leave the device unattended during operation. radiant heater IRS 2000 E...
  • Page 4 Do not stay in the device's immediate vicinity for too Trotec. long. Do not look directly into the device for too long. Observe the minimum distances. radiant heater IRS 2000 E...
  • Page 5: Information About The Device

    Operation chapter. 650W 1350W 2000W TIMER Designation On / off switch heater Control panel Remote control Foot Grille Heating rod radiant heater IRS 2000 E...
  • Page 6: Transport And Storage

    • Set the device up in an upright and stable position. • Do not position the device directly below a wall socket. • Make sure that the device cannot come into contact with moisture or water. radiant heater IRS 2000 E...
  • Page 7: Operation

    An acoustic signal is emitted each time a setting is activated. Warning of hot surface The grille (5) heats up during operation and can still be hot after switch-off. Do not touch the grille (5) during operation, wait until it has cooled down after switch-off. radiant heater IRS 2000 E...
  • Page 8 2. Use the heating level button (11) at the device or the heating capacity buttons on the remote control (3) to select the desired heating level. ð The device now starts heating at the selected heating level. radiant heater IRS 2000 E...
  • Page 9 • Check the fuse. Switch off any other devices to reduce the load on the line. • Contact a specialist electrical company. The device slightly vibrates during switch-on and then stops vibrating: • Slight vibrations during switch-on are a normal process. No measures are required. radiant heater IRS 2000 E...
  • Page 10: Technical Annex

    5 kg abrasive cleaners to dampen the cloth. Remote control batteries type CR 2025 / 3 V Wipe the housing dry after cleaning. Dirt on the heating rods should be removed with a long brush with soft bristles. radiant heater IRS 2000 E...
  • Page 11: Disposal

    Directive 2006/66/EC of the European Parliament and of the Council of 6 September 2006 on batteries and accumulators. Please dispose of batteries and accumulators according to the relevant legal requirements. radiant heater IRS 2000 E...
  • Page 13 Trotec GmbH & Co. KG Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.com...