Fault Finding; Technical Data; Disposal - Grundfos CIM 060 Installation And Operating Instructions Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

6. Fault finding

Fault
1.
The connection
between the Grundfos
GO and the CIM 060
has failed.
2.
No internal
communication
between the CIM 060
and the product. (LED
flashing red).
See also installation and operating instructions of the
product in question and of the Grundfos GO.
The above manuals can be found in the Grundfos
Product Center: product-selection.grundfos.com

7. Technical data

Communication range
of on-board antenna
Storage temperature
Operating temperature -20 to 85 °C
Operating and storage
humidity
External antenna

8. Disposal

This product or parts of it must be disposed of in an
environmentally sound way:
1. Use the public or private waste collection service.
2. If this is not possible, contact the nearest
Grundfos company or service workshop.
Possible cause
a)
Power is off.
b)
The product has no connection
code or has a different
connection code.
c)
The connection time has
elapsed (30 seconds).
The CIM 060 is defective.
a)
The CIM 060 is not fitted
correctly on the product.
b)
The connecting plug on the
CIM 060 is defective.
c)
The connecting plug on the
product is defective.
10 m
-20 to 85 °C
0-95 % RH
Non-condensing
2.4 GHz RF signal
SMA connector
Max. cable length 2.9 m
Subject to alterations.
Remedy
Turn power on. Wait until the LED ceases
to flash.
Connect via the connection button on the
module. See
5.1 Via the connection
button.
Reselect the product in Grundfos GO.
Note: If the connection button has not
been pressed within 30 seconds from the
time the product was selected in
Grundfos GO, the connection is
cancelled.
Replace the CIM 060.
Check that the module is fitted correctly.
Check the connecting plug on the
CIM 060 (one of the pins might be
damaged).
Check the connecting plug on the
product.
9