Fig. 23
Fig. 24
Perform filter mat change as follows:
Open the louver grilles of the inlet filter (Fig. 23).
Remove the filter pad.
Insert the new filter pad into the louver grille. Ensure that the smooth side (-A- Fig. 24) of the filter pad faces the air
inlet side.
Place the louver grille back onto the filter housing.
Changing times for the filter mat
The operating modes and the quality of the suctioned air (e.g., dust content) has a strong influence on the filter service
life.
The filter should be checked on a weekly basis, eventually daily basis, for dust build-up.
In these cases the intervals between changes may be shorter.