Change Oil Filter Cartridge - Gardner Denver L Series Service Manual

Table of Contents

Advertisement

Fig. 16
1
Oil reservoir
2
Oil filler cap R1"
3
Oil-level indicator
4
Upper fill level
5
Lower fill level
Bleed ball valve R1/2"
6
7
Drain hose
The changing intervals can be found in the
maintenance schedule.
Perform oil changes as follows:
Turn off the screw compressor unit, secure it
against accidental restarts and make sure that the
demister vessel is depressurized.
Slowly open the oil screw plug (-2- Fig. 16) to
relieve the screw compressor of any residual
pressure in the system
Remove the oil screw plug
Open the oil drain (-6- Fig. 16) from the pressure
reservoir
Drain the oil at operating temperature through the
drain hose (-7- Fig. 16)
Close the oil drain
Fill with oil up to the mark "maximum oil level"
(-4- Fig. 16) (approx. 6.2 US-Gal.)
Close the oil screw plug
Run the screw compressor for approximately
2 minutes
Check for leaks
Shut off the screw compressor
Wait at least 5 minutes until the oil has settled, i.e.
until the air has bubbled out.
Check the oil level, (see Section 7.5)
The oil level must lie between the "maximum oil level"
(-4- Fig. 16) and "minimum oil level" (-5- Fig. 16).
If necessary, top up the oil.
Oil change interval
Operating conditions (e.g., coolant temperatures), the
type of operation and the quality of the intake air (e.g.,
dust content, ratio of gaseous foreign substances such
as SO
the oil change intervals.
In these cases, the operational life of the oil must be
checked by performing an oil analysis (also see Section
10.13).

10.5 Change oil filter cartridge

Air/oil under pressure will cause severe
personal injury or death.
 Shut down the compressor, relieve the
13-25-638 v03
Page 43
and solvent vapors) have a strong influence on
2
DANGER
system of all pressure, disconnect,
lockout and tagout the power supply to
the compressor package before
removing valves, caps, plugs, fittings,
bolts and filters.
CAUTION

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L55-75fLrs55-75f

Table of Contents