Gardner Denver L Series Service Manual page 41

Table of Contents

Advertisement

Maintenance Schedule - L Series
Check air/oil reservoir oil level
Check operation of the machine, is it loading and
unloading properly
Check discharge pressure and temperature
Check control panel for advisory text messages
Inspect, Clean if necessary Cooler / Fan
Replace oil filter element
Replace air filter element
Oil Sample
Replace cool air inlet filter pad
Control Box Filter (if app.)
Visually check for leakage Shaft Seal
Replace Lubricant *
Replace Air/Oil Separator
Inspect, clean if necessary scavenge line, replace check
Inspect, service if necessary Inlet Valve
Inspect, replace if necessary Min. Pressure/Check Valve
Check pressure relief valve
Inspect, repair if necessary the Condensate Drains
Inspect, replace if necessary Solenoid Valves / Vacuum
Switch
Inspect, replace if necessary Blow-down Valve
Inspect, replace if necessary Thermistor Probes
Inspect, replace if necessary Pressure Transducer
Inspect, replace if necessary Control Valves and Pressure
Regulator
Inspect, replace if necessary Thermal Mixing Valve
Inspect, replace if necessary the drive Coupling Spider
Inspect, replace if necessary Hoses
*
Drain and change as indicated by oil Analysis report, hour life rating of lubricant or every 12 months,
whichever occurs first.
These maintenance intervals must be kept!
It's in your own best interest you should check off maintenance work in the maintenance schedule as it is done.
valve
13-25-638 v03
Page 41

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L55-75fLrs55-75f