Advertisement

Quick Links

CoolRepeat is a connectivity solution that allows for
patient temperature information from an indwelling patient
temperature probe to be communicated to the Blanketrol
cooling/warming system and a patient monitor.
Blanketrol Console
1.
Connect preattached cable from Blanketrol CoolRepeat
to stereo input on top right side of Blanketrol console.
2.
Connect cable from Blanketrol CoolRepeat "monitor"
output to temperature input on patient monitor.
3.
Connect extension cable from Blanketrol CoolRepeat
"thermistor" output to patient temperature probe.
4.
After connecting all cables, attach Blanketrol CoolRepeat
below cable input on body of Blanketrol console; internal
magnets will ensure it remains in place.
NOTE:
After connecting device, please wait 30 seconds
before initiating therapy as device will proceed with
automatic self-test at start up; device 'turns on' when
thermistor is connected.
CoolRepeat
Patient Monitor
English
Patient / Thermistor
106726-001 Rev. 2
®

Advertisement

Table of Contents
loading

Summary of Contents for Gentherm BLANKETROL CoolRepeat

  • Page 1 Connect extension cable from Blanketrol CoolRepeat “thermistor” output to patient temperature probe. After connecting all cables, attach Blanketrol CoolRepeat below cable input on body of Blanketrol console; internal magnets will ensure it remains in place.
  • Page 2 Blanketrol CoolRepeat Instructions for Use ® ® Graphic Symbols for Medical Device Labeling WARNINGS: • Blanketrol CoolRepeat must be used with a Attention: See Instructions for Use Blanketrol system. • Once thermistor and cables are connected, verify that temperature consistently displays on console Date of Manufacture and monitor.
  • Page 3: Maintenance

    Blanketrol CoolRepeat Instructions for Use ® ® Battery Specifi cations Indicator Power Requirements – DC Battery Indicator light on the top edge of the device emits light patterns to indicate several conditions: NOTE: Flashing Green – Normal Operation when unit is ‘on’ Lithium-ion 9V battery recommended for maximum (thermistor cable is plugged in).
  • Page 4: Catalog Number

    Electromagnetic Emissions The Blanketrol CoolRepeat Console is intended for use in the electromagnetic environment specifi ed below. The customer or the user of the Blanketrol CoolRepeat device should assure that it is used in such an environment. Emissions Tests Compliance...
  • Page 5: Electromagnetic Immunity

    Electromagnetic Immunity The Blanketrol CoolRepeat device, Model 25-01 is intended for use in the electromagnetic environment specifi ed below. The customer or the user of the Blanketrol CoolRepeat device, Model 25-01 should assure that it is used in such an environment.
  • Page 6 RF transmitters, an electromagnetic site survey should be considered. If the measure fi eld strength in the location in which the Blanketrol CoolRepeat device is used exceeds the applicable RF compliance level above, the Blanketrol CoolRepeat device should be observed to verify normal operation.
  • Page 7: Recommended Separation Distances

    Recommended Separation Distances Between Portable and Mobile RF Communications Equipment and the Blanketrol CoolRepeat Device. The Blanketrol CoolRepeat device, Model 25-01, is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the...
  • Page 8 Blanketrol CoolRepeat Instructions for Use ® ® This page intentionally left blank. This page intentionally left blank.
  • Page 9 Distributed by: Gentherm Medical 12011 Mosteller Road Cincinnati, OH 45241 1-513-772-8810 www.gentherm.com ZOLL International Holdings B.V. Newtonweg 18 6662 PV ELST The Netherlands Tel: 31 481 366410 ZOLL Circulation Inc. 2000 Ringwood Avenue San Jose, CA 95131 U.S.A. t: +1-408-541-2140...

Table of Contents