Electrolux ERS09E37HW Installation Instructions Manual page 12

Hide thumbs Also See for ERS09E37HW:

Advertisement

Available languages
  • EN

Available languages

12 www.electrolux.com
2. Direct the air vent toward an area
without obstacles.
3. Install the unit at the site where it is
exposed to as little wind as possible,
especially in areas where it is
frequently windy.
4. If the installation site is exposed to
heavy winds, such as in coastal areas,
place the unit along the widest part of
the wall or use protective plates.
5. Be sure there is no obstacle which
blocks exhausting air, including
schrubs or bushes.
Fig.10
NOTE:
Settlement of outdoor unit. Anchor the
outdoor unit tightly and horizontally
and nut 10mm diameter (Purchased
separately).
Fig.11
Air Inlet
Strong Wind
Air Inlet
Air Outlet
3.2.2 Condensate drainage of
outdoor unit (only for heat pump
model)
1. During heating operation, the
condensate and defrosting water
should be drained out reliably through
the drain hose.
2. Install the outdoor drain connector in
the drain-water hole on the chassis of
outdoor unit, and attach the drain hose
to the connector so that the waste
water formed in the outdoor unit can
be drained out.
3. The drain-water hole must be plugged.
Whether to plug other holes will be
determined by the installer according
to actual conditions.
4. In case of a drain hose, the unit must
be installed on a base more than 3cm
height.
Fig.12
3.3 Refrigerant piping
connection
NOTE:
Unit comes with 7.5m tubing bundle. It
is not recommended to cut. If too long,
loop for excess.
Keep original bend so not kinking of
the tube occurs.
Drain-water
hole
Chassis
Drain
connecter
Hose of inner
(not provided)