3. DOMO GRI series only:
4. Install the unit:
DOMO, DOMO GRI - Installation, Operation and Maintenance Manual
a) Remove one of the three support feet by unscrewing the M8x25 screw.
b) Re-tighten the screw.
Tightening torque: 13 Nm (115 lbf·in).
c) Repeat a) and b) for the other two feet.
a) Screw the discharge port to the sliding bracket, placing the seal included in the kit
between the two.
b) Attach the chain to the handle.
c) Slide the sliding bracket through the guide pipes and lower the unit in the tank,
supporting it with the chain until the end.
d) Attach the end of the chain to the edge of the tank.
e) Secure the supply cord to the edge of the tank with a stop.
2
2x
2x
6
3
5
4x
7
9
4
1
8
en – Original instructions
DOMO_M0002_A_de
15