How to write the settings
The procedures of writing the settings that have been previously
read out with use of the White Balance Setting Tool are as follows.
1)Press
[Connection
Setting...]
communication settings.
2) Turn ON the power of Information Display.
3) Press [LoadFile...] button to select the setting file.
4) Press [Write] button, and the set values are written.
5) Confirm that the "K" mark does not appear on the upper left of
screen.
If the "K" mark is displayed, please perform the writing
procedures once again.
<CAUTION>
When the following messages: "This Monitor is not Support. Is
write processing continued?," "Writing data is not for this monitor.
Is write processing continued?," "Serial Number is different
between monitor and writing data. Is write processing
continued?," or "Model Name is different between monitor and
writing data. Is write processing continued?" are displayed, the
data you are trying to write may not be the one which the display
previously read out.
Check if it is the right data, and perform the writing once again.
15-4. WHEN REPLACING THE PANEL OR WHEN
AN OLD PWB DOES NOT OPERATE
The procedures of writing the settings that have been previously
readout with use of the White Balance Setting Tool are as follows.
The procedures of resetting the settings to default are as follows.
1) Press [Connection Setting] button to configure the
communication settings.
2) Turn ON the power of Information Display.
3) Press [Reset] button. The White Balance settings are set to
default.
4) Confirm that the "K" mark does not appear on the upper left of
screen.
If the "K" mark is displayed, please perform the resetting
procedures once again.
<CAUTION>
-
When the following messages: "This Monitor is not Support. Is
write processing continued?," "Writing data is not for this monitor.
Is write processing continued?" or "Model Name is different
between monitor and writing data. Is write processing continued?"
are displayed, the display which you are trying to initialize may not
be this model. Check if it is the right model, and perform the
initialization procedures once again.
(MEMO)
PN-L803C/80TC3 SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4- 31
button
to
configure
the
WHEN THE MESSAGE: "TIME OUT. CANNOT
CONNECT.
PLEASE CONFIRM SETTING." IS DISPLAYED
-
Check the power state of the connected Information Display.
If "Read & Save" is executed when the display is in a STANDBY
state, it fails in rare cases. Make sure that the display is in an
ON state, and then press [Read & Save...] button again to read
the settings.
-
Check that the PC which you use is properly connected to the
Information Display via a RS-232C cable.
WHEN THE MESSAGE: "CANNOT OPEN INTERFACE.
CANNOT CONNECT. PLEASE CONFIRM SETTING." IS
DISPLAYED
-
Check if you are trying to use the COM Port which is in use by
some other tool. If the COM Port is being used, terminate the
tool and then press [Read & Save...] button again to read the
setting values.
WHEN THE MESSAGE: "THIS MONITOR IS NOT
SUPPORT.
IS XXXX PROCESSING CONTINUED?" IS DISPLAYED
-
The connected display is not the model which this tool supports.
Please use the right tool that supports the connected display.