System Error - Marantz SR7300 Service Manual

Av surround amplifier
Hide thumbs Also See for SR7300:
Table of Contents

Advertisement

12. SYSTEM ERROR

The CPU inside the unit monitors peripheral interfaces and if a trouble is detected the following information is displayed on
the FLD.
1.
Trouble in DSP
If communication with DSP is troubled more than 2 seconds, FLD shows below.
C
H
E
C
* This display stays and sound is muted.
2.
Trouble in RS-232C
If communication with RS-232C of panja system is troubled more than 2 seconds, FLD shows below.
C
H
E
C
3.
Trouble in EEPROM
If data from EEPROM(QU70) does not match, FLD shows below.
C
H
E
C
* After displaying it, Back-up Data is reset to default.
4.
Trouble in EEPROM I/F
If communication with EEPROM(QU70) is troubled more than 2 seconds, FLD shows below.
C
H
E
C
5.
Trouble in 5V Supply
If 5V supply to P604(DSP/CPU PCB) is troubled, FLD shows below.
C
H
E
C
6.
Trouble in Power Amplifi er
If DC offset, over-current, over-heat, trouble in main transformer is detected, FLD shows below.
P
R
O
T
* If a trouble is detected upon power on, CPU turns off the speaker relay. And if the trouble is not recovered within
2 seconds, CPU turns the unit into stand-by. If DC offset or over-current is detected on power on status, the
speaker relay is turned off, and if over-heat, trouble in main transformer is detected, the unit turns into stand-by
immediately.