Technical Specifications; Troubleshooting; Disposal Information - Samoa U-VISION 383 400 Parts And Technical Service Manual

Control meter
Hide thumbs Also See for U-VISION 383 400:
Table of Contents

Advertisement

Available languages

Available languages

EN
BYPASS MODE
Under these mode, a "trip" meter is available in order to
simplify the execution of individual dispenses. To do this,
just press and hold the "power" button until the displayed
quantity changes to zero (9). From now on, the dispensed
volume will increase from zero ("trip" meter). The "total"
meter will now be displayed on the bottom right corner of
the screen (10), next to the units.
CAUTION:
In by-pass mode the amount of fluid dispensed is not
registered in the monitoring system.

TECHNICAL SPECIFICATIONS

Unit compatibility
Batteries
Connectivity
Temperature operation range -10 ºC a 60 ºC
Weight
Display

TROUBLESHOOTING

Symptom
Lack of connection
The screen does not turn on
The unit is configured but it does
not work

DISPOSAL INFORMATION

6
838 842 R. 07/17
SAMOA Industrial, S.A. · Pol. Ind. Porceyo, I-14 · Camino del Fontán, 831 · 33392 - Gijón - Spain · Tel.: +34 985 381 488 · www.samoaindustrial.com
SAMOA oil control gun
4 x AA / LR6
Bluetooth LE
420 g (0.92 lb)
Dot matrix 128x64 with
backlight
Possible cause
Unit not configured
Wrong batteries assembly
Batteries run out of energy
Wrong pairing
The symbol above means that according to local laws and regulations your product and/or its
battery must be disposed of separately from household waste. When this product reaches its end of
life, take it to a collection point designated by local authorities. The separate collection and recycling
of your product and/or its battery at the time of disposal will help conserve natural resources and
ensure that it is recycled in a manner that protects human health and the environment.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1)
this device may not cause harmful interference, and (2) this
device must accept any interference received, including
interference That may cause undesired operation.
Solution
Consult pairing instructions
Check batteries polarity
Replace batteries
Check that the unit is paired with the
correct hose reel
10
Fig. 13
9

Advertisement

Table of Contents
loading

Table of Contents