Page 2
State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Supermicro's total liability for all claims will not exceed the price paid for the hardware product.
Page 3
If you have any questions, please contact our support team at: support@supermicro.com This manual may be periodically updated without notice. Please check the Supermicro website for possible updates to the manual revision level. Secure Data Deletion A secure data deletion tool designed to fully erase all data from storage devices can be found on our website: https://www.supermicro.com/about/policies/disclaimer.cfm?url=/wdl/utility/...
Preface Contents Chapter 1 Introduction 1.1 Overview ..........................7 AIOM Options ........................7 1.2 System Features .........................8 Front View ...........................8 Drive Carrier Indicators ....................9 Control Panel .........................10 Top View ..........................11 1.3 Motherboard Layout ......................13 Quick Reference .......................14 Motherboard Block Diagram .....................15 Chapter 2 Installation and Setup 2.1 Unpacking the System .......................16 2.2 Installing or Removing the Blade Unit ................17 Installing a Blade Unit into the Enclosure .................17...
Page 5
Preface 2.10 System Cooling .........................38 Air Shrouds ........................38 Checking the Server Air Flow ...................39 Overheating ........................39 Chapter 3 Motherboard Connections 3.1 Headers and Connectors ....................40 3.2 Jumpers ..........................42 3.3 LED Indicators ........................43 Chapter 4 Software 4.1 Installing the Operating System ..................44 Linux Installation with Two Storage Drives—Note ............44 Microsoft Windows OS Installation ...................45 4.2 Driver Installation ........................47...
Page 6
6.10 Reporting an Issue ......................64 Technical Support Procedures ..................64 Returning Merchandise for Service ...................64 Vendor Support Filing System ..................65 6.11 Feedback ..........................65 6.12 Contacting Supermicro ......................66 Appendix A BIOS POST Codes Appendix B Standardized Warning Statements for AC Systems Appendix C System Specifications...
System Cooling One air shroud Form Factor 4U height; 6.5” x 1.75” x 23.5” (depth) (16.5 x 4.4 x 59.7 cm) A Quick Reference Guide can be found on the product page of the Supermicro website. SBA-4114S-C2N: (web page link); SBA-4114S-T2N:...
Chapter 1: Introduction 1.2 System Features The following views of the system display the main features. Refer to Appendix C for additional specifications. Front View AIOMs Storage Drives Service/Asset Tab Control Panel Latch Lever with BMC Password Figure 1-1. Front View Logical Storage Drive Numbers Item Description...
Chapter 1: Introduction Drive Carrier Indicators Each drive carrier has two LED indicators: an activity indicator and a status indicator. For RAID configurations using a controller, the meaning of the status indicator is described in the table below. For OS RAID or non-RAID configurations, some LED indications are not supported, such as hot spare.
Chapter 1: Introduction Control Panel Power Button Power LED KVM/UID LED NIC LED System Fail LED Figure 1-2. Control Panel Control Panel Features Features Color/State Description The main power switch applies or removes primary power from the Power Button power supply to the server but maintains standby power. Green Power on Power LED...
Chapter 1: Introduction 1.3 Motherboard Layout Below is a layout of the BH12SSi-M25 motherboard with jumper, connector and LED locations shown. See the following page for descriptions. For detailed descriptions, pinout information and jumper settings, refer to Chapter 3 or the Motherboard Manual.
Chapter 2: Installation and Setup Chapter 2 Installation and Setup This chapter provides instructions on installing and replacing main system components. To prevent compatibility issues, only use components that match the specifications or part numbers. Twenty blade modules may be installed into a blade enclosure, depending upon your enclosure.
Chapter 2: Installation and Setup 2.2 Installing or Removing the Blade Unit Installing a Blade Unit into the Enclosure 1. Pull the latch lever out, and push the blade into its bay. Caution: Insert the blade carefully so the rear connectors are not damaged. 2.
Chapter 2: Installation and Setup 2.3 Powering Up or Down Each blade unit may be powered on and off independently from the rest of the blades in the enclosure. Powering Up a Blade Unit A blade unit may be powered up in two ways: •...
Chapter 2: Installation and Setup 2.4 Removing the Cover When the blade has been removed from the enclosure, the top cover can be removed to access the components. • Remove the screw and slide the cover toward the rear and off. Figure 2-2.
When receiving a motherboard without a processor pre-installed, make sure that the plastic CPU socket cap is in place and none of the socket pins are bent; otherwise, contact your retailer immediately. • Refer to the SuperMicro website for updates on CPU support.
Page 21
Chapter 2: Installation and Setup Installing the Processor and Heatsink Begin by removing power from the system as described in Section 2.3. 1. Use a Torx T20 driver to loosen the screws holding down Force Frame in the sequence of 3-2-1. The screws are numbered on the Force Frame next to each screw hole. Tighten to 16.1 kgf-cm (14 lbf-in) of torque.
Page 22
Chapter 2: Installation and Setup 2. The spring-loaded Force Frame will raise up after the last screw (#1) is removed. Gently allow it to lift up to its stopping position. Figure 2-4. Raising the Force Frame 3. Lift the Rail Frame up by gripping the lift tabs near the front end of the rail frame. While keeping a secure grip of the Rail Frame, lift it to a position so you can do the next step of removing the External Cap.
Page 23
Chapter 2: Installation and Setup 4. Remove the External Cap from the Rail Frame by pulling it upwards through the rail guides on the Rail Frame. External Cap PnP Cover Cap Figure 2-6. Removing the External Cap 5. The CPU Package is shipped from the factory with the blue Carrier Frame pre- assembled.
Page 24
Chapter 2: Installation and Setup Note: You can only install the CPU inside the socket in one direction with the handle at the top. Make sure that it is properly inserted into the CPU socket before closing the Rail Frame plate.
Page 25
Chapter 2: Installation and Setup Figure 2-9. Securing the Force Frame 10. Replace the screws in the order 1-2-3, tightening to 16.1 kgf-cm (14 lbf-in) of torque. The Force Frame secures both the Rail Frame and CPU Package. Caution: Tightening must be executed in proper 1-2-3 sequence to avoid causing catastrophic damage to the socket or CPU Package.
Page 26
Chapter 2: Installation and Setup 11. Lower the heatsink down till it rests securely on CPU Package over the four screw holes on the socket frame. Figure 2-11. Mounting the Heatsink 12. Using a Torx T20 driver in a diagonal pattern as below, tighten the four heatsink screws halfway and then tighten them evenly to 16.1 kgf-cm (14.0 lbf-in) of torque.
Page 27
Chapter 2: Installation and Setup Removing a Heatsink We do not recommend removing the heatsink. If necessary, please follow the instructions below to prevent damage to the CPU or the CPU socket. Note: Wait for the heatsink to cool down before removing it. 1.
Chapter 2: Installation and Setup 2.6 Memory Memory Support The BH12SSi-M25 supports up to 2TB of 3DS ECC DDR4 3200 MHz speed, RDIMM/ LRDIMM/3DS/NVDIMM memory in eight slots. Check the SuperMicro website for possible updates to memory support. DDR4 Memory Support DIMM Capacity (GB)
Page 29
Chapter 2: Installation and Setup MH17 MH15 BAR CODE H12SSW-iN MAC CODE SXB1C JSLIM2 DIMM A1 DIMM H1 DIMM B1 JVRM1 DIMM G1 DIMM C1 DIMM F1 DIMM D1 DIMM E1 FAN4 Figure 2-13. DIMM Numbering FAN3 FAN2 Memory Module Distribution Channel 1 DIMM (not recommended) ü...
Chapter 2: Installation and Setup Installing Memory ESD Precautions Electrostatic Discharge (ESD) can damage electronic com ponents including memory modules. To avoid damaging DIMM modules, it is important to handle them carefully. The following measures are generally sufficient. • Use a grounded wrist strap designed to prevent static discharge. •...
Chapter 2: Installation and Setup 2.7 Motherboard Battery The motherboard uses non-volatile memory to retain system information when system power is removed. This memory is powered by a lithium battery residing on the motherboard. Replacing the Battery When the blade has been removed from the enclosure and the top cover removed. 1.
These carriers also help promote proper airflow. Carriers without drives must remain in the chassis for proper airflow. Note: Enterprise level storage drives are recommended for use in Supermicro systems. For information on recommended drives, visit the Supermicro website.
Page 33
Chapter 2: Installation and Setup Removing a Hot-Swap Drive Carrier from the Chassis 1. Press the release button on the drive carrier, which will extend the drive carrier handle. 2. Use the drive carrier handle to pull the drive out of the chassis. Figure 2-17.
Page 34
Chapter 2: Installation and Setup Installing a Drive 1. Remove the dummy drive, which comes pre-installed in the drive carrier. Pull out the two spring locking clasps and lift out the dummy drive. Post Post Locking Clasps SB414_25HDD_TRAY_ASSY_REF Figure 2-18. Removing the Dummy Drive from a Carrier 2.
Chapter 2: Installation and Setup Hot-Swap for NVMe Drives Supermicro servers support NVMe surprise hot-swap. For even better data security, NVMe orderly hot-swap is recommended. NVMe drives can be ejected and replaced remotely using the BMC Dashboard. Ejecting a Drive 1.
Chapter 2: Installation and Setup Checking the Temperature of an NVMe Drive There are two ways to check using the BMC Dashboard. Checking a Drive • BMC Dashboard > Server Health > NVMe SSD – Shows the temperatures of all NVMe drives.
Chapter 2: Installation and Setup 2.9 AIOMs The system supports two advanced input/output modules (AIOMs). Installing an AIOM 1. Pull up the locking latch. 2. Insert the cards in to the slot. 3. Push the latch down to secure the modules. Locking Latch Figure 2-21.
Chapter 2: Installation and Setup 2.10 System Cooling Air Shrouds Air shrouds concentrate airflow to maximize fan efficiency. These do not require screws to install. Installing the Air Shrouds • Position the air shrouds as illustrated in the figure below, sliding the front notch over the pin on the fan tray.
Chapter 2: Installation and Setup Checking the Server Air Flow • Make sure there are no objects to obstruct airflow in and out of the server. • Do not operate the server without drives or drive carriers in the drive bays. •...
The JTPM1 header is used to connect a Trusted Platform Module (TPM)/Port 80, which is available from Supermicro. A TPM/Port 80 connector is a security device that supports encryption and authentication in hard drives. It allows the motherboard to deny access if the TPM associated with the storage drive is not installed in the system.
Page 41
Chapter 3: Motherboard Connections A. 2X PCIE Gen 4 x16 connector for MCIO cable B. 2X M.2 Connector (PCIE Gen 4 x4 or 2 SATA support) C. Front panel control connector (LED and power button) D. PCIE Gen 4 x16 Mezzanine card connector E.
Chapter 3: Motherboard Connections 3.2 Jumpers To modify the operation of the motherboard, jumpers are used to choose between optional settings. Jumpers create shorts between two pins to change the function associated with it. Pin 1 is identified with a square solder pad on the printed circuit board. See the motherboard layout page for jumper locations.
Chapter 3: Motherboard Connections 3.3 LED Indicators Onboard Power LED (PWR LED) When the PWR LED is illuminated, the system is turned on and all the system power rails are ready. When the system is turned off, or any one of the system power rails fails, this LED will turn off.
An operating system (OS) must be installed on each blade module. Blades with Microsoft Windows OS and blades with Linux OS can operate within the same blade enclosure. Refer to the SuperMicro web site for a list of supported operating systems. Installing by using PXE Boot Preboot Execution Environment (PXE) is used to boot a computer over a network.
If you will be using RAID, you must configure RAID settings before installing the Windows OS and the RAID driver. Refer to the RAID Configuration User Guides posted on our website at www.supermicro.com/support/manuals. Installing the OS 1. Create a method to access the MS Windows installation ISO file. That might be a DVD, perhaps using an external USB/SATA DVD drive, or a USB flash drive, or the BMC KVM console.
Page 46
Chapter 4: Software 3. During Windows Setup, continue to the dialog where you select the drives on which to install Windows. If the disk you want to use is not listed, click on “Load driver” link at the bottom left corner. Figure 4-2.
DVD. (You may also use a utility to extract the ISO file if preferred.) Another option is to go to the Supermicro website at www.supermicro.com/products/. Find the product page for your motherboard, and "Download the Latest Drivers and Utilities".
4.3 SuperDoctor ® The Supermicro SuperDoctor 5 is a program that functions in a command-line or web-based interface for Windows and Linux operating systems. The program monitors such system health information as CPU temperature, system voltages, system power consumption, fan speed, and provides alerts via email or Simple Network Management Protocol (SNMP).
This can be found on a sticker on the chassis and a sticker on the motherboard. The sticker also displays the BMC MAC address. If necessary, the password can be reset using the Supermicro IPMICFG tool. Figure 4-5. BMC Password Label The sticker can be found on the pull-out service tag at the front of the chassis.
The JTPM1 header is used to connect a Trusted Platform Module (TPM). A TPM is a security device that supports encryption and authentication in hard drives. It enables the motherboard to deny access if the TPM associated with the hard drive is not installed in the system. Details and installation procedures are at: http://www.supermicro.com/manuals/other/TPM.pdf.
Chapter 6 Troubleshooting and Support 6.1 Information Resources Website A great deal of information is available on the Supermicro website, supermicro.com. Figure 6-1. Supermicro Website Click the menu icon, the three bars in the upper right corner, then select: •...
Security Center for recent security notices Supermicro Phone and Addresses 6.2 BMC Interface The system supports a Baseboard Management Controller (BMC) interface. It provides remote access, monitoring and management. There are several BIOS settings related to the BMC.
Chapter 6: Troubleshooting and Support 6.3 Troubleshooting Procedures Use the following procedures to troubleshoot your system. If you have followed all of the procedures below and still need assistance, refer to the Technical Support Procedures Returning Merchandise for Service sections in this chapter. Power down the system before changing any non hot-swap hardware components.
Chapter 6: Troubleshooting and Support No Video 1. If the power is on but you have no video, remove all the add-on cards and cables. 2. As you try to power up the system, note any beep codes. Refer to the next section for details on beep codes.
Page 55
2. Memory support: Make sure that the memory modules are supported by testing the modules using memtest86 or a similar utility. Note: Refer to the product page on our website at http://www.supermicro.com for memory and CPU support and updates. 3. HDD support: Make sure that all hard disk drives (HDDs) work properly. Replace the bad HDDs with good ones.
When BIOS performs the Power On Self Test, it writes checkpoint codes to I/O port 0080h. If the computer cannot complete the boot process, a diagnostic card can be attached to the computer to read I/O port 0080h (Supermicro p/n AOC-LPC80-20). For information on AMI updates, please refer to http://www.ami.com/products/.
In the event of a processor internal error (IERR) that crashes your system, you may want to provide information to support staff. You can download a crash dump of status information using the BMC Dashboard. The BMC manual is available at www.supermicro.com/manuals/ other/BMC_Users_Guide_X12_H12.pdf. Check Error Log 1.
Warning: Do not upgrade the BIOS unless your system has a BIOS-related issue. Flashing the wrong BIOS can cause irreparable damage to the system. In no event shall Supermicro be liable for direct, indirect, special, incidental, or consequential damages arising from a BIOS update.
Page 59
USB device or a writable CD/DVD. Note 1: If you cannot locate the "Super.ROM" file in your drive disk, visit our website at www.supermicro.com to download the BIOS package. Extract the BIOS binary image into a USB flash device and rename it "Super.ROM" for the BIOS recovery use.
Page 60
Chapter 6: Troubleshooting and Support Note: At this point, you may decide if you want to start the BIOS recovery. If you decide to proceed with BIOS recovery, follow the procedures below. 4. When the screen as shown above displays, use the arrow keys to select the item "Proceed with flash update"...
Page 61
Chapter 6: Troubleshooting and Support 7. Press <Del> continuously during system boot to enter the BIOS Setup utility. From the top of the tool bar, select Boot to enter the submenu. From the submenu list, select Boot Option #1 as shown below. Then, set Boot Option #1 to [UEFI AP:UEFI: Built-in EFI Shell]. Press <F4>...
Page 62
Chapter 6: Troubleshooting and Support Note: Do not interrupt this process until the BIOS flashing is complete. 9. The screen above indicates that the BIOS update process is complete. When you see the screen above, unplug the AC power cable from the power supply, clear CMOS, and plug the AC power cable in the power supply again to power on the system.
Chapter 6: Troubleshooting and Support 6.7 CMOS Clear JBT1 is used to clear CMOS, which will also clear any passwords. Instead of pins, this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS. To Clear CMOS 1.
6.9 Where to Get Replacement Components If you need replacement parts for your system, to ensure the highest level of professional service and technical support, purchase exclusively from our Supermicro Authorized Distributors/System Integrators/Resellers. A list can be found at: http://www.supermicro.com.
For issues related to Red Hat Enterprise Linux, since it is a subscription based OS, contact your account representative. 6.11 Feedback Supermicro values your feedback as we strive to improve our customer experience in all facets of our business. To provide feedback on our manuals, please email us at techwriterteam@...
Chapter 6: Troubleshooting and Support 6.12 Contacting Supermicro Headquarters Address: Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) Website: www.supermicro.com Europe Address: Super Micro Computer B.V.
Appendix A: BIOS POST Codes Appendix A BIOS POST Codes A.1 BIOS POST Messages During the Power-On Self-Test (POST), the BIOS will check for problems. If a problem is found, the BIOS will activate an alarm or display a message. The following is a list of such BIOS messages.
Page 68
Appendix A: BIOS POST Codes BIOS POST Messages BIOS Message Description Previous POST did not complete successfully. POST loads default values and offers to run Setup. If the failure was caused by incorrect values and Previous boot incomplete - they are not corrected, the next boot will likely fail. On systems with control of Default configuration used wait states, improper Setup settings can also terminate POST and cause this error on the next boot.
Page 69
Appendix A: BIOS POST Codes BIOS POST Messages BIOS Message Description nnnn kB Extended RAM Where nnnn is the amount of RAM in kilobytes successfully tested. Passed nnnn Cache SRAM Passed Where nnnn is the amount of system cache in kilobytes successfully tested. nnnn kB Shadow RAM Passed Where nnnn is the amount of shadow RAM in kilobytes successfully tested.
Page 70
Appendix A: BIOS POST Codes Terminal POST Errors If a terminal type of error occurs, BIOS will shut down the system. Before doing so, BIOS will write the error to port 80h, attempt to initialize video and write the error in the top left corner of the screen.
Page 71
Appendix A: BIOS POST Codes Terminal POST Errors Code Description Initialize POST Memory Manager Clear 512 kB base RAM 1-3-4-1 RAM failure on address line xxxx* 1-3-4-3 RAM failure on data bits xxxx* of low byte of memory bus Enable cache before system BIOS shadow Test CPU bus-clock frequency Initialize Phoenix Dispatch Manager Warm start shut down...
Page 72
Appendix A: BIOS POST Codes Terminal POST Errors Code Description 2-2-3-1 Test for unexpected interrupts Initialize POST display service Display prompt “Press F2 to enter SETUP” Disable CPU cache Test RAM between 512 and 640 kB Test extended memory Test extended memory address lines Jump to UserPatch1 Configure advanced cache registers Initialize Multi Processor APIC...
Page 73
Appendix A: BIOS POST Codes Terminal POST Errors Code Description Configure Motherboard Configurable Devices (optional) Initialize BIOS Data Area Enable Non-Maskable Interrupts (NMIs) Initialize Extended BIOS Data Area Test and initialize PS/2 mouse Initialize floppy controller Determine number of ATA drives (optional) Initialize hard-disk controllers Initialize local-bus hard-disk controllers Jump to UserPatch2...
Page 74
Appendix A: BIOS POST Codes Terminal POST Errors Code Description POST done - prepare to boot operating system 1 One short beep before boot Terminate QuietBoot (optional) Check password (optional) Initialize ACPI BIOS Prepare Boot Initialize SMBIOS Initialize PnP Option ROMs Clear parity checkers Display MultiBoot menu Clear screen (optional)
Page 75
Appendix A: BIOS POST Codes Terminal POST Errors Code Description The following are for the boot block in Flash ROM: Boot Block Flash ROM Terminal POST Errors Code Description Initialize the chipset Initialize the bridge Initialize the CPU Initialize system timer Initialize system I/O Check force recovery boot Checksum BIOS ROM...
Page 76
Appendix A: BIOS POST Codes Boot Block Flash ROM Terminal POST Errors Code Description Initialize System Management Manager Output one beep Clear Huge Segment Boot to Mini DOS Boot to Full DOS If the BIOS detects error 2C, 2E, or 30 (base 512K RAM error), it displays an additional word- bitmap (xxxx) indicating the address line or bits that failed.
Supermicro's Technical Support department for assistance. Only certified technicians should attempt to install or configure components. Read this appendix in its entirety before installing or configuring components in the Supermicro chassis. These warnings may also be found on our website at https://www.supermicro.com/about/...
Page 78
Appendix B: Warning Statements Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut. Suchen Sie mit der am Ende jeder Warnung angegebenen Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert wurden.
Page 79
Appendix B: Warning Statements . ٌ ا ك ً ف حالة و ٌ يك أى تتسبب ف اصابة جسذ ة ٌ هذا الزهز ع ٌ خطز !تحذ ز قبل أى تعول عىل أي هعذات،يك عىل علن بالوخاطز ال ا ٌجوة عي الذوائز ٍ...
Page 80
Appendix B: Warning Statements Warnung Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen. ¡Advertencia! Lea las instrucciones de instalación antes de conectar el sistema a la red de alimentación. Attention Avant de brancher le système sur la source d'alimentation, consulter les directives d'installation. .יש...
Page 81
Appendix B: Warning Statements Warnung Dieses Produkt ist darauf angewiesen, dass im Gebäude ein Kurzschluss- bzw. Überstromschutz installiert ist. Stellen Sie sicher, dass der Nennwert der Schutzvorrichtung nicht mehr als: 250 V, 20 A beträgt. ¡Advertencia! Este equipo utiliza el sistema de protección contra cortocircuitos (o sobrecorrientes) del edificio.
Page 82
Appendix B: Warning Statements Power Disconnection Warning Warning! The system must be disconnected from all sources of power and the power cord removed from the power supply module(s) before accessing the chassis interior to install or remove system components. 電源切断の警告 システムコンポーネントの取り付けまたは取り外しのために、...
Page 83
Appendix B: Warning Statements אזהרה מפני ניתוק חשמלי !אזהרה יש לנתק את המערכת מכל מקורות החשמל ויש להסיר את כבל החשמלי מהספק .לפני גישה לחלק הפנימי של המארז לצורך התקנת או הסרת רכיבים يجب فصم اننظاو من جميع مصادر انطاقت وإ ز انت سهك انكهرباء من وحدة امداد انطاقت...
Page 84
Appendix B: Warning Statements Equipment Installation Warning! Only trained and qualified personnel should be allowed to install, replace, or service this equipment. 機器の設置 トレーニングを受け認定された人だけがこの装置の設置、 交換、 またはサービスを許可されていま す。 警告 只有经过培训且具有资格的人员才能进行此设备的安装、更换和维修。 警告 只有經過受訓且具資格人員才可安裝、更換與維修此設備。 Warnung Das Installieren, Ersetzen oder Bedienen dieser Ausrüstung sollte nur geschultem, qualifiziertem Personal gestattet werden.
Page 85
Appendix B: Warning Statements Restricted Area Warning! This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security. (This warning does not apply to workstations). アクセス制限区域...
Page 86
Appendix B: Warning Statements אזור עם גישה מוגבלת !אזהרה יש להתקין את היחידה באזורים שיש בהם הגבלת גישה. הגישה ניתנת בעזרת (.'כלי אבטחה בלבד (מפתח, מנעול וכד . تخصيص هذه انىحذة نترك ب ُ ها ف مناطق محظورة تم ، م َ كن انىصىل إن منطقت محظورة فقط من خالل استخذاو أداة خاصت أو...
Page 87
Appendix B: Warning Statements Warnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp. Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers. Attention Danger d'explosion si la pile n'est pas remplacée correctement. Ne la remplacer que par une pile de type semblable ou équivalent, recommandée par le fabricant.
Page 88
Appendix B: Warning Statements Redundant Power Supplies Warning! This unit might have more than one power supply connection. All connec- tions must be removed to de-energize the unit. 冗長電源装置 このユニッ トは複数の電源装置が接続されている場合があります。 ユニッ トの電源を切るためには、 すべての接続を取り外さなければなりません。 警告 此部件连接的电源可能不止一个,必须将所有电源断开才能停止给该部件供电。 警告 此裝置連接的電源可能不只一個,必須切斷所有電源才能停止對該裝置的供電。 Warnung Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass der Einheit kein trom zugeführt wird, müssen alle Verbindungen entfernt werden.
Page 89
Appendix B: Warning Statements אם קיים יותר מספק אחד !אזהרה ליחדה יש יותר מחיבור אחד של ספק. יש להסיר את כל החיבורים על מנת לרוקן .את היחידה . قد يكون لهذا الجهاز عدة اتصاالت بوحدات امداد الطاقة يجب إ ز الة كافة االتصاالت لعسل الوحدة عن الكهرباء 경고! 이...
Page 90
Appendix B: Warning Statements Warnung Wenn das System in Betrieb ist, treten auf der Rückwandplatine gefährliche Spannungen oder Energien auf. Vorsicht bei der Wartung. ¡Advertencia! Cuando el sistema está en funcionamiento, el voltaje del plano trasero es peligroso. Tenga cuidado cuando lo revise. Attention Lorsque le système est en fonctionnement, des tensions électriques circulent sur le fond de panier.
Page 91
Appendix B: Warning Statements Comply with Local and National Electrical Codes Warning! Installation of the equipment must comply with local and national electrical codes. 地方および国の電気規格に準拠 機器の取り付けはその地方および国の電気規格に準拠する必要があります。 警告 设备安装必须符合本地与本国电气法规。 警告 設備安裝必須符合本地與本國電氣法規。 Warnung Die Installation der Geräte muss den Sicherheitsstandards entsprechen. ¡Advertencia! La instalacion del equipo debe cumplir con las normas de electricidad locales y nacionales.
Page 92
Appendix B: Warning Statements Product Disposal Warning! Ultimate disposal of this product should be handled according to all national laws and regulations. 製品の廃棄 この製品を廃棄処分する場合、 国の関係する全ての法律 ・ 条例に従い処理する必要があります。 警告 本产品的废弃处理应根据所有国家的法律和规章进行。 警告 本產品的廢棄處理應根據所有國家的法律和規章進行。 Warnung Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen des Landes erfolgen.
Page 93
Appendix B: Warning Statements Hot Swap Fan Warning Warning! Hazardous moving parts. Keep away from moving fan blades. The fans might still be turning when you remove the fan assembly from the chassis. Keep fingers, screwdrivers, and other objects away from the openings in the fan assembly's housing. ファン...
Page 94
Electrical Appliance and Material Safety Law prohibits the use of UL or CSA -certified cables (that have UL/CSA shown on the cord) for any other electrical devices than products designated by Supermicro only. 電源コードとACアダプター...
Page 95
Verbindungskabeln, Stromkabeln und/oder Adapater, die Ihre örtlichen Sicherheitsstandards einhalten. Der Gebrauch von anderen Kabeln und Adapter können Fehlfunktionen oder Feuer verursachen. Die Richtlinien untersagen das Nutzen von UL oder CAS zertifizierten Kabeln (mit UL/CSA gekennzeichnet), an Geräten oder Produkten die nicht mit Supermicro gekennzeichnet sind. ¡Advertencia! Cuando instale el producto, utilice la conexión provista o designada o procure cables, Cables...
Appendix C: System Specifications Appendix C System Specifications Processor AMD EPYC 7003/7002 Series processor in Socket SP3 Chipset System on Chip (LBG-R) BIOS 256Mb MX25L2567 BIOS Memory Eight DIMM slots, 2TB 3DS ECC RDIMM/LRDIMM DDR4; up to 3200MHz Storage Drives Two 2.5"...
Need help?
Do you have a question about the SuperBlade SBA-4114S-C2N and is the answer not in the manual?
Questions and answers