Wall mounted commercial reverse osmosis systems (8 pages)
Summary of Contents for Watts GTS450C
Page 1
Please read carefully before proceeding with installation. Your failure to follow any attached instructions or operating parameters may lead to the product’s failure. Save manual for future reference MODEL GTS450C Refer to enclosed warranty for operating parameters to ensure proper use with your water supply. Page 1...
Page 2
This manual is used for several variations of the same system. Your system may vary slightly from the pictures or descriptions contained in this manual. It is the end users responsibility to ensure that this system is installed according to all local codes and regulations. Thank you for your purchase of a state of the art Reverse Osmosis (RO) water treatment system.
With proper installation and maintenance, this system will provide you with high quality water for years to come. All of our water enhancement products are rigorously tested by independent laboratories for safety and reliability. Table of Contents Operational Parameters ........................4 Contents of Reverse Osmosis System ....................
Operational Parameters Installation must comply with State and local plumbing regulations. Do not use with water that is micro- biologically unsafe or of unknown quality without adequate disinfection before or after the system. System is intended to be installed using the cold water supply only. Operating Temperatures: Maximum 100°F (37.8°C) Minimum 40°F (4.4°C)
4 Stage Reverse Osmosis System Plumbing 1/4” x 1/4” Union Parts List Flow Restrictor Pre-Filter, sediment FPMB5-978 Check Valve Insert Pre-Filter, carbon WCBCS975 Membrane W-1812-50 Post Filter AICRO Faucet FU-WDF-103NSF Red Drain Tube Metal Tank FRO-132-WH Compression Nut Plastic Tank ROPRO4-W Feed water valve F560080...
(If you are already using it for a sprayer or soap dispenser, see step 1) Porcelain sinks are extremely hard and can crack or chip easily. Use extreme caution when drilling. Watts accepts no responsibility for damage resulting from the installation of faucet. Diamond tip bit recommended.
Adapt-a-Valve Installation Caution: Water supply line to the system must be from the cold water supply line only. Hot water will severely damage your system. White Washer 3/8” Configuration Cold 1/2” Configuration (With Brass Fittings) (Without Brass Supply Supply * Insert White Washer Fittings) Cold Supply...
Mount the Reverse Osmosis Faucet Refer to installation instructions found on faucet box. Drain Saddle Installation - Fits standard 1 ¼” – 1 ½” drain pipes Caution: If you have a garbage disposal, do not install the drain saddle near it. Installation of the drain saddle must be either above the garbage disposal, or if a second sink drain is available, install it above the cross bar on the second drain.
3/8” Tube Fitting Drain Saddle Step 13B-1 Red Tube from Reverse Osmosis System Remove the white 1/4” x 1/4” plastic union and two plastic tube 1/4” Drain Tube Union Fitting inserts from the parts bag. Locate the 1/4” drain tube from the RO faucet and the 1/4”...
Tank Valve Installation Step 17 Choose your configuration (A - Metal Tank or B - Plastic Tank): Metal Tank Step 18A Locate the Teflon tape roll in the parts bag. Teflon tape must be applied in a clockwise direction. Wrap 5 to 7 turns around the male pipe threads (MPT) on the Stainless Steel fitting on top of the tank.
Congratulations! You have completed the installation of new your Reverse Osmosis system. Please Follow the Startup Instructions. Start up Instructions Turn on the incoming cold water at the angle stop valve and the Step 1 Adapt-a-Valve. Check the system for leaks and tighten any fittings as necessary.
MAINTENANCE & TROUBLESHOOTING MAINTENANCE & TROUBLESHOOTING 6 Month System Maintenance Items needed: √ Stage 1 - Sediment Filter √ Stage 2 - Carbon Block Filter Step 1 Turn off the incoming water supply to the RO system at the adapt-a- valve.
Annual Maintenance √ Stage 1 - Sediment Filter √ Stage 2 - Carbon Block Filter √ Stage 4 - 10” Post Filter √ 1/2 Cup of hydrogen peroxide or common household bleach. Sanitizing of unit is recommended. Note: Step 1 Perform steps 1 through 5 in the Six Month System Maintenance (Page 12).
Normally, a membrane would be replaced during a semiannual or annual filter change. However, if at any time you notice a reduction in water production or an unpleasant taste in the reverse osmosis water, it could be time to replace the membrane. Watts recommends replacing the membrane when TDS reduction falls below 75%.
Check Air Pressure in the Tank Important: Check air pressure only when tank is empty of water! Check air pressure in the storage tank when you notice a decrease in available water from the RO system. Air can be added with a bicycle pump using the schrader valve that is located on the lower side of the tank behind the blue plastic cap.
1. Low/Slow Production Low Water Pressure Assure a minimum of 40 psi incoming water pressure. Watts sells a booster pump if home water pressure is low. Make sure water supply is turned on and Adapta Valve is all the way open.
This Watts reverse osmosis system is designed to remove up to 98% of pentavalent arsenic. It will not convert trivalent arsenic to pentavalent arsenic. Under laboratory standard testing conditions, this system reduced 0.30 mg/L (ppm) pentavalent...
Service Record Date of Purchase:__________ Date of Install:___________ Installed by:__________________ 2nd stage Post Filter 1st stage Date Carbon Carbon Membrane Sediment (6 months) (1 year) (2-5 years) (6 months) NOTES: Page 19...
If any part of your Reverse Osmosis System is defective in workmanship (excluding replaceable filters and membranes), return unit after obtaining a return authorization (see below), less tank, within 1 year of original retail purchase, WATTS will repair or, at WATTS option, replace the system at no charge.
Need help?
Do you have a question about the GTS450C and is the answer not in the manual?
Questions and answers