3.3.2 Segnali di sicurezza

ATTENZIONE
• DARE TENSIONE AI RISCALDATORI OLIO DEL CARTER ALMENO 12 ORE PRIMA
DELL'AVVIAMENTO DELL'UNITÀ NEGLI INTERVALLI DI FUNZIONAMENTO (AD
ES. PAUSA DEL FINE SETTIMANA) TOGLIERE L'ALIMENTAZIONE ELETTRICA.
• L'UNITÀ È MUNITA DI UN RITARDATORE ANTIRICIRCOLO E DI DISPOSITIVO PER
LA RIPARTENZA AUTOMATICA.
• PRIMA DI APRIRE IL SEZIONATORE FERMARE L'UNITÀ AGENDO SUGLI APPOSITI
INTERRUTTORI DI MARCIA O IN ASSENZA SUL COMANDO A DISTANZA.
• PRIMA DI ACCEDERE A PARTI INTERNE DELL'UNITÀ TOGLIERE TENSIONE
APRENDO IL SEZIONATORE GENERALE.
WARNING
• SUPPLY THE CRANKCASE HEATERS AT LEAST 12 HOURS BEFORE STARTING
THE UNIT DURING TEMPORARY STOP PERIODS (LIKE WEEK÷ENDSI NEVER
DISCONNECT ELECTRICAL SUPPLY TO THE UNIT.
• THE UNIT IS PROVIDED WITH DELAY RELAY AND WITH AUTOMATIC RESTART
DEVICE.
• BEFORE OPENING THE MAIN SWITCH, STOP THE UNIT BY ACTING ON THE
SUITABLE RUNNING SWITCHES OR THESE ARE IF NOT PRESENT, ON THE
REMOTE CONTROL.
• BEFORE SERVICING THE INNER COMPONENTS, DISCONNECT ELECTRICAL
SUPPLY BY OPENING THE MAIN SWITCH.
ACHTUNG
• DIE KURBELWANNENHEIZUNG MINDESTENS 12 STUNDEN VOR DER INBETRIEB-
NAHME DES GERATS UNTER SPANNUNG SETZEN DIE KURBELWANNENHEIZUNG
WAHREND DER STILLSTANDSZEITEN DES GERATS NICHT AUSSCHALTEN.
• DAS GERAT IST MIT SCHALTVERZOGERUNGSTIMER UND VORRICHTUNG FÜR
AUTOMATISCHEN WIEDERANLAUF AUSGESTATTET.
• VOR DEM OFFNEN DES HAUPTSCHALTERS SETZEN SIE DAS GERAT DURCH
BETATIGUNG DER ENTSPRECHENDEN BETRIEBSSCHALTER ODER WENN DIESE
NICHT VORHANDEN SIND, DURCH FERNBEDIENUNG AUSSER BETRIEB.
• BEVOR MAN DIE INTERNE GERATEKOMPONENTEN BERUHRT. MUSS DER
HAUPTSCHALTER GEOFFNET WERDEN.
NOTICE
• FOURNIR TENSION AUX RECHAUFFERS DU CARTER AU MOINS 12 HEURES
AVANT QUE L'UNITÉ SOIT DÉMARÉE NE COUPEZ PAS LA TENSION AUX
RÉCHAFFEURS PENDANTS DES COURTES PERIODES D'ARRET DE L'UNITE.
TELS QUE LE WEEK-END.
• L'UNITÉ EST EQUIPPÉE DE RELAIS ANTI COURT-CYCLE ET D'UN DISPOSITIF
POUR LE REDEMARRAGE AUTOMATIQUE.
• AVANT D'OUVRIR LE SÉCTIONNEUR GENERAL ARRETEZ L'UNITÉ EN AGISSANT
SUR LES INTERRUPTEURS DE MARCHE OU AU CAS OU IL N'YA PAS SUR LE
COMMENDE Á DISTANCE.
• AVANT DE TOUCHER LES COMPOSANT INTERNES A L'UNITÉ, COUPER LA
TENSION EN OUVRANT LE SECTIONNEUR GÉNÉRAL.
- PRESENZA DI ORGANI IN MOVIMENTO
- PRESENCE OF MOVING OBJECTS
- ANWESENHEIT VON GEGENSTÄNDEN
IN BEWEGUNG
- PRESENCE DES ORGANS EN MOUVEMENT
10
TSR 18 ÷ 131
3.3.2 Safety signs
1
-INSTALLARE SEMPRE UN FILTRO ACQUA SUL CIRCUITO IDRAULICO
A PROTEZIONE DELL' EVAPORATORE.
6
-PLEASE BUILT ALWAYS A WATER FILTER ON THE HYDRAULIC
CIRCUIT TO PROTECT THE EVAPORATOR.
-EIN WASSERFILTER AUF DEM HYDRALISCHEN KREIS ZUM SCHUTZ
DES VERDAMPFERS IMMER EINBAUEN.
-INSTALLER TOUJOURS UN FILTRE DE L' EAU SUR LE CIRCUIT
HYDRAULIQUE A PROTECTION DE L' EVAPORATEUR.
INGRESSO ACQUA REFRIGERATA
CHILLED WATER INLET
KALTWASSEREINTRITT
ENTRÉE EAU GLACÉE
USCITA ACQUA REFRIGERATA
CHILLED WATER OUTLET
KALTWASSERAUSTRITT
SORTIE EAU GLACÉE
SFIATO ARIA
AIR PURGE
4
ENTLÜFTUNGSVENTIL
PURGE AIR
5
!
!
ATTENZIONE
ATTENTION
VORSICHT
2
3
7