The following steps create an IP address and subnet mask for GIG 0/1.
1. At the # prompt, enter config terminal.
2. At the (config)# prompt, enter interface gig 0/1 to access the configuration parameters for the Gigabit
Ethernet port located on the front of the unit.
3. Enter ip address 10.10.10.1 255.255.255.0 to assign an IP address to the Gigabit Ethernet port using a
24-bit subnet mask.
4. Enter no shutdown to activate the interface to pass data.
5. Enter exit to exit the Ethernet interface commands and return to the Global Configuration mode.
6. Enter ip route 0.0.0.0 0.0.0.0 192.168.1.254 to add a default route to the route table. 0.0.0.0 is the
default route and the default subnet mask, and 192.168.1.254 is the next-hop IP address to which the
AOS unit should send all of its traffic. You will need to enter the proper route, subnet mask, and gateway
for your network. This information is typically provided by an Internet service provider (ISP) or local
network administrator.
7. Enter do write memory to save the current configuration.
E
T
NABLE
ELNET
The following steps enable user login parameters for Telnet access by changing the password from the default
(password) and enabling security login on Telnet lines.
1. Verify that the prompt of your unit displays (config)#.
2. Enter line telnet 0 4 to change the configuration parameters for the Telnet sessions.
3. Enter login to prompt users with a login prompt for Telnet access.
4. Enter password adtran to change the login password for the Telnet sessions.
5. Enter exit to return to the Global Configuration mode.
6. Verify that the prompt of your unit displays (config)#.
7. Enter do write memory to save the current configuration.
N
V
6240/6250 S
ET
ANTA
Feature
IP Address
DHCP
Auto-Config
User Name
Password
HTTP Server
Event History
IP Routing
R
F
ESTORING
On units that have a console port, you cannot restore the factory defaults, but must rather erase the device's
configuration and then reconfigure the unit to operate correctly for your network. To erase the unit's current
configuration, follow these steps:
1.
Access the unit's CLI and enter enable at the > prompt.
2.
Enter erase startup-config at the # prompt. The device will have a blank configuration upon reboot.
3.
Enter reload at the # prompt to begin restarting the device. When prompted to save configuration, enter
no. When prompted to reboot, enter yes.
4.
Upon reboot, you will have to reconfigure the unit using the CRAFT port. Follow the steps outlined here or
in the technical note,
61700202G1-13D
U
L
SER
OGIN
ERIES
D
ACTORY
EFAULTS
Accessing the Web Interface in AOS
A
CCESS
D
EFAULTS
Default Value
10.10.10.1
Client Enabled (NetVanta 6250 Series only)
Zero Touch Provisioning Enabled (NetVanta 6250
Series only)
admin
password
Enabled
On
Enabled
available at https://supportforums.adtran.com.
3

Advertisement

loading

This manual is also suitable for:

Netvanta 6250 series4740202g104740202g204700252f14700254f14700256f1