Download Print this page

Environmental Operating Conditions & Physical Specifications; Front-Panel User Interface - Wegener DTV720 Installation & Quick Start Manual

Transport stream multiplexor receives
Hide thumbs Also See for DTV720:

Advertisement

Environmental Operating Conditions & Physical Specifications
Use
Altitude
Temperature Range
Relative Humidity (max.)
Weight
Dimensions (H x W x D)
Input Power Rating

Front-panel User Interface

Note that from any screen, pressing the ESC key twice will return you to the Home Screen.
Main-level Screens
Home Screen (rotates through status of each input) The following are
examples of typical home screens:
R F 1 C h a n : X X
S N R Y Y . Y E r r S e c : Z Z Z Z
Where XX is the broadcast channel number, YY.Y is the signal-to-noise
ratio, and ZZZZ is the number of errored seconds since the last reset of the
counter or the last lock of input.
A S I 1 E n a b l e d
E r r S e c s : 0 0 0 0
Press the 4
4 key to go to Alarms/Warnings.
Press the ENT key to view the second-level Serial Number and Application
Software Version Number screen.
Alarms/Warnings
V i e w A l a r m s / W a r n i n g s
Press the ENT key to view any active alarms or warnings on the second-
level Alarms/Warnings Message screen.
Press the 4
4 key to go to Clear Errored Seconds (if counter is non-zero) or
Program Setup.
Press the ESC key to go to the Home Screen.
Clear Errored Seconds
C l e a r E r r o r e d S e c s
P r e s s < E N T >
Press the ENT to clear the errored seconds counter.
Press the 4
4 key to go to the Input Setup screen.
Press the 3
3 key to go to Alarms/Warnings.
Press the ESC key to go to the Home Screen.
800043-02 Rev. A
Indoor
Up to 2000 meters
o
0
C to +50
80% for temperatures up to 31
humidity at 40
10.6 pounds or 4.81 kilograms
3.5"x 19"x 10.5" or 88.9 mm x 482.6 mm x 266.7 mm
90-132Vac & 175-264Vac, 43 Watt, 50/60 Hz
8 V S B
Where XXXXXX is the unit's six-digit serial number and YYY is the version number
of the unit's currently installed application software.
Press the ESC key to go to the Home Screen.
Alarms/Warnings Message Screen
Any active alarms or warnings are described here.
Press the 4
Press the ESC key to return to the Alarms/Warnings screen.
Page 3 of 6
o
C
o
C decreasing linearly to 50% relative
o
C.
Second-level Screens
Serial Number and Application Software Version Number Screen
S / N : X X X X X X
V E R : Y Y Y
N o A l a r m s o r W a r n i n g
4 key to view the next alarm or warning (if more than one).
July 21, 2004

Advertisement

loading