Thermo Scientific 88882013 Quick Start Manual

Thermo Scientific 88882013 Quick Start Manual

Digital platform rocker

Advertisement

Quick Links

In the United States:
In Canada:
For customer service, call 1-800-766-7000
For customer service, call 1-800-234-7437
To fax an order, use 1-800-926-1166
To fax an order, use 1-800-463-2996
To order online: thermofisher.com
To order online: thermofisher.ca
Find out more at
thermofisher.com
©2021 Thermo Fisher Scientific Inc.
All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified.
Digital Platform Rocker
88882013 & 88882014
Operating Manual
Revision A . 04 01 2021

Advertisement

Table of Contents
loading

Summary of Contents for Thermo Scientific 88882013

  • Page 1 Digital Platform Rocker 88882013 & 88882014 In the United States: In Canada: For customer service, call 1-800-766-7000 For customer service, call 1-800-234-7437 To fax an order, use 1-800-926-1166 To fax an order, use 1-800-463-2996 To order online: thermofisher.com To order online: thermofisher.ca Operating Manual Revision A .
  • Page 2: Table Of Contents

    Contents Section 1 Important Information Disposing of Product Section 2 Introduction Feature Section 3 Inspection and Installation Packing List Connections Structure Diagram Section 4 Overview Specifications Environmental Conditions Safety Instructions Loads, Angle and Speed Section 5 Operation Control Panel Installation of Two Trays Installation Settings Section 6 Safety Tips and Maintenance...
  • Page 3: Section 1 Important Information

    Ignoring the following warnings could operating and request the service. Do not let the product take any strong Welcome to Thermo Scientific Digital cause serious injuries or even fatal shock or vibration. It could cause Platform Rocker. This Digital Platform Keep out of the direct sunlight.
  • Page 4: Section 3 Inspection And Installation

    Power Cord 3.1 Packing List Power Adaptor Table -1. Packing List Main Body Description Catalog Number Figure Speed/Tilt setting knob Digital Time setting knob 88882013 88882014 Platform Rocker Dimpled Rubber Mat 3.3 Structure Diagram (Installed) General Power Adaptor Dimpled Rubber Mat...
  • Page 5: Section 4 Overview

    Section 4 Overview 4.1 Specifications 4.3 Safety Instructions Rotation Speed Speed Range..............1~70rpm Please read the entire instruction manual Position of Loads Display Accuracy..............1rpm before operating the Digital Platform Place the loads in the recommended Speed Accuracy....±1rpm≤50rpm, ±2rpm>50rpm Rocker. positions below: 1.
  • Page 6: Loads, Angle And Speed

    Section 5 Operation This chapter covers the control panel and its operation. 5.1 Control Panel ④ ③ ② ① Time Speed/Tilt rpm/degree Asymmetric loading or unloading may affect the Speed normal operation of the instrument and may Stop Mode Tilt even cause unpredictable damage.
  • Page 7: Installation Of Two Trays

    5.2 Installation of Two Trays 5.3 Installation counter clockwise/to increase speed, Only accessories that meet the 1. Connect all the components according rotate the knob clockwise then press manufacturer's specifications shall be to the figures shown on page 4 of this used.
  • Page 8: Section 6 Safety Tips And Maintenance

    Section 6 Safety Tips and Maintenance Run and Stop Alarm System Safety Tips Warning: Avoid dripping detergent or Press “ ” button and the instrument Err1: If running speed does not match 1. Use independent power supply. water into the inside of the instrument Stop will start running with the specified the setting speed, the instrument will...
  • Page 9: Section 7 Troubleshooting

    Shut down and restart, useless, General Power Adaptor Operational obstruction Err1 88870127 250VAC 10A 1.8m please contact Thermo Scientific w/AUS, CN plug Keep record for maintenance Other General Power Adaptor 88870128 250VAC 16A 1.8m w/EU plug...
  • Page 10: Section 9 Warranty Information

    Section 9 Warranty Section 10 Compliance THERMO FISHER SCIENTIFIC THIS WARRANTY IS EXCLUSIVE AND IN 1. European Union the instruction manual, may cause STANDARD PRODUCT WARRANTY LIEU OF ALL OTHER WARRANTIES, harmful interference to radio The European voltage models WHETHER WRITTEN, ORAL OR IMPLIED. communications.
  • Page 11 appropriate. exemptions of the regulation due to their companies in each EU Member State, 4.1.2 RoHS - Europe application. and this product should be disposed of Thermo Fisher Scientific is determined 4.1.3 RoHS - China or recycled through them. Further to reduce the impact we have on the This product complies with the information on our compliance with...