Operation - EINHELL MR 920 LCD Original Operating Instructions

Oil-filled radiator
Hide thumbs Also See for MR 920 LCD:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 9
Anleitung_MR_920_LCD_SPK7:_
Slide the fastening bar (1) under the radiator
element, engage it in the mounting (2) and secure
it with the wing nut (3). Repeat the above on the
last space between the ribs.

7. Operation

Note! The actual room temperature is not indicated
correctly for the first 20 or so minutes after the heater
is switched on.
Note! The electronic room temperature control will
switch the heater on and off automatically to maintain
the room temperature at an almost constant level.
However, this presupposes that the radiator has
sufficient output to cover the heating requirements
for the room.
7.1 Function switch (Fig. 4)
Button 1: Switches the device on and off, switches
on heat setting 1 or heat setting 2.
Button 2: Sets the desired room temperature, the
switch OFF time and the switch ON time.
Button 3: Changes over from "°F" (degrees
Fahrenheit) to "°C" (degrees Celsius).
Button 4: Decreases the desired room temperature,
the switch OFF time and the switch ON time.
Button 5: Increases the desired room temperature,
the switch OFF time and the switch ON time.
7.1.1 Continuous operation
Press button 1 (Power) once when the appliance
is off. The appliance switches on and runs in heat
setting 2 (SS). The temperature displayed equals
the room temperature measured by the appliance.
Press button 1 a second time and the appliance
switches to heat setting 1 (S); press it again and
the appliances switches to "OFF".
Note: When the appliance is switched on it will run
continuously until it is switched off again manually as
previously described.
7.1.2 Switching on and off by the room
temperature control
Switch on the appliance as previously described.
Press the button 2 until the "Thermometer" symbol
flashes in LCD display.
Set the desired room temperature with the button
4 or 5.
The "Thermometer" then shines with a steady light
14.06.2010
8:38 Uhr
Seite 11
and the room temperature measured by the
appliance is indicated.
When the room temperature rises above the
desired level, the appliance switches off the
heater and the temperature indicator flashes.
When the room temperature drops below the
desired level, the heater switches on again. The
temperature indicator shows the measured room
temperature.
Example: with a desired room temperature of 21°C
the appliance switches off at 22°C and on at 20°C.
7.1.3 Programming the switch OFF time
When the appliance is running (the control lamp
shines) you can set a switch OFF time for the heater
from 1h to 10h. The appliance then switches off
automatically once the set time has elapsed.
Note: Set the desired room temperature as
previously described in section 6.1.2. When the
desired temperature is reached the appliance will
switch off the heater, and when the temperature
drops below the desired level it will switch the heater
on again, even if the set OFF time has not yet
elapsed.
Press button 2 until "AUTO OFF" flashes in the
LCD display.
Set the desired switch OFF time with the button 4
or 5.
"AUTO OFF" then shines with a steady light and
the set OFF time is indicated. The appliance
shows the time remaining up to the end of the set
OFF time.
7.1.4 Programming the switch ON time
When the appliance is running (the control lamp
shines) you can set a switch ON time for the heater
from 1h to 10h. The heater then switches on when
the set time has elapsed. If no switch OFF time was
programmed yet (see 6.1.3) the appliance will switch
off automatically after 10h. The heater can be
switched off manually at any time with the button 1
(Power).
Note: Set the desired room temperature as
previously described in section 6.1.2. When the
desired temperature is reached the appliance will
switch off the heater, and when the temperature
drops below the desired level it will switch the heater
on again.
Press button 2 until "AUTO ON" flashes in the
GB
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

23.383.50

Table of Contents