Mitsubishi Electric MS-CP13VA Service Manual page 50

Split-type air conditioners
Hide thumbs Also See for MS-CP13VA:
Table of Contents

Advertisement

OPERATING PROCEDURE
3. Removing the nozzle assembly
(1) Remove the panel and the corner box. (Refer to sec-
tion 1.)
(2) Remove the electrical cover. (Refer to section 2.)
(3) Remove the electrical side cover, and disconnect the
vane motor connector.
(4) Pull out the drain hose from the nozzle assembly, and
remove the nozzle assembly.
4. Removing the vertical vane motor
(1) Remove the nozzle assembly. (Refer to section 3.)
(2) Remove the crank of the vertical vane motor unit from
the arm of the vertical vane.
(3) Remove the screw of the vertical vane motor unit, and
pull the vertical vane motor unit.
(4) Remove the screws of the vertical vane motor unit
cover.
(5) Remove the crank of the vertical vane motor unit from
the shaft of the vane motor.
(6) Remove the vertical vane motor from the vertical vane
motor unit.
(7) Disconnect the connector of vertical vane motor from
the vertical vane motor.
5. Removing the horizontal vane motor
(1) Remove the nozzle assembly. (Refer to section 3.)
(2) Remove the screws of the horizontal vane motor unit,
and pull out the horizontal vane motor unit.
(3) Disconnect the connector from the horizontal vane
motor.
(4) Remove the screws of the horizontal vane motor.
(5) Remove the horizontal vane motor.
OBH782A
PHOTOS/FIGURES
Photo 3
Photo 4
Screws of the vertical vane motor unit cover
Photo 5
Screws of the vertical vane motor unit cover
Photo 6
Screws of the horizontal vane motor unit
50
Screw of electrical
box
Screw of the vertical
vane motor unit
Crank of the vertical
vane motor unit
Crank of the vertical
vane motor unit
Screw of the vertical
vane motor unit
Screws of the
horizontal vane
motor

Advertisement

Table of Contents
loading

Table of Contents