Mitsubishi Electric MS-CP13VA Service Manual page 16

Split-type air conditioners
Hide thumbs Also See for MS-CP13VA:
Table of Contents

Advertisement

When the system is restarted after 2 hours and more, the operation mode is determined by the room temperature at
start-up of the operation.
Operation time chart
Example
Previous operation
COOL mode of
"I FEEL CONTROL"
or COOL mode
(4) The initial set temperature is decided by the initial room temperature.
Mode
COOL mode of
"I FEEL CONTROL"
DRY mode of
more than 13 °C, less than 25 °C
"I FEEL CONTROL"
*1 When the system is restarted with the remote controller, the system operates with the previous set temperature regard-
less of the room temperature at restart.
The set temperature is calculated by the previous set temperature.
(5) Temperature buttons
In "I FEEL CONTROL" mode, set temperature is decided by the microprocessor based on the room temperature.
In addition, set temperature can be controlled by TOO WARM or TOO COOL buttons when you feel too cool or too warm.
Each time TOO WARM or TOO COOL button is pressed, the indoor unit receives the signal and emits a beep tone.
Fuzzy control
When TOO COOL or TOO WARM button is pressed, the microprocessor changes the set temperature, considering the
room temperature, the frequency of pressing TOO COOL or TOO WARM button and the user's preference to heat or
cold. So this is called "Fuzzy control" and it works only in "I FEEL CONTROL" mode.
In DRY mode of "I FEEL CONTROL", the set temperature does not change.
... To raise the set temperature 1 ~ 2
... To lower the set temperature 1 ~ 2
OBH782A
Restart
COOL or DRY mode of
"I FEEL CONTROL" that
determined by room
temperature at start-up
of the operation.
Initial room temperature
26 °C or more
25 °C to 26 °C
Initial set temperature
24 °C
Initial room temperature
°C
minus 2
Initial room temperature
°C
minus 2
16
*1

Advertisement

Table of Contents
loading