Service Functions - Mitsubishi Electric MS-CP13VA Service Manual

Split-type air conditioners
Hide thumbs Also See for MS-CP13VA:
Table of Contents

Advertisement

7

SERVICE FUNCTIONS

MS-CP13VA MS-CP18VA MS-CP24VA MS-CP30VA
7-1. TIMER SHORT MODE
For service, the following set time can be shortened by bridging the timer short mode point on the electronic control P.C.
board. (Refer to 9-7.)
Set time: 3 minutes → 3 seconds (It takes 3 minutes for the compressor to start operation. However, the starting time is
shortened by bridging the timer short mode.)
7-2. P.C. BOARD MODIFICATION FOR INDIVIDUAL OPERATION
A maximum of 4 indoor units with wireless remote controllers can be used in a room.
In this case, to operate each indoor unit individually by each remote controller, P.C. boards of remote controller must be
modified according to the number of the indoor unit.
How to modify the remote controller P.C. board
Remove batteries before modification.
The board has a print as shown below:
The P.C. board has the print "J1" and "J2". Solder "J1" and "J2" according to the number of indoor unit as shown in Table 1.
After modification, press the RESET button.
Table 1
1 unit operation
No. 1 unit
No modification
No. 2 unit
No. 3 unit
No. 4 unit
How to set the remote controller exclusively for particular indoor unit
After you turn the breaker ON, the first remote controller that sends the signal to the indoor unit will be regarded as the remote
controller for the indoor unit.
The indoor unit will only accept the signal from the remote controller that has been assigned to the indoor unit once they are set.
The setting will be cancelled if the breaker is turned OFF, or the power supply is shut down.
Please conduct the above setting once again after the power has been restored.
OBH782A
2 units operation
Same as at left
Solder J1
J1
J2
3 units operation
Same as at left
Same as at left
Solder J2
12
NOTE: For modification, take out
the batteries and press the
OFF/ON (stop/operate)
button 2 or 3 times at first.
After modification, put back
the batteries then press the
RESET button.
4 units operation
Same as at left
Same as at left
Same as at left
Solder both J1 and J2

Advertisement

Table of Contents
loading

Table of Contents