On releasing the key, a new value is displayed which, if timed operation was
000
enabled, indicates the delay timer setting between the start of the cycle and the
actual start of the heating phase and is indicated on the lower display with
t D
do not want to edit the value, press the
the
and
keys edit the value and the
memory.
Identical configuration procedures are used for the subsequent
respectively set the time in which the heating element stays at the heating temperature selected
and the time to allow cooling of the heating element before indicating the operating cycle has
concluded.
The next configuration sets the temperature differential compared to the heating
000
temperature which defines when the heating element can be considered arrived to the
working temperature and is indicated on the bottom display with
D r
want to edit the value, press the
and
keys edit the value and the
The top display shows
tun
procedure for parameter acquisition of the heating element. The
return to temperature display. To start the procedure, press and keep pressed the
1 0
key until the counter on the second line reaches zero.
Warning: The counter may continue to restart even if you press and hold the button signalling
that the conditions are not right to start the procedure. Probably the heating element is not yet at
room temperature, temperature required for success of the "tuning" phase, or the device is active
in heating mode. Release the button, disable heating, and wait a few minutes before trying again.
At this point, the first top led switches on to indicate the procedure, divided in 3 parts, has started.
After approx. 1-2 minutes, the procedure will end displaying, if everything was successfully
completed, the three flashing leds and two numbers on the display. The
return to normal operation with temperature display. (for further information on the procedure,
refer to the relevant section of the manual)

Extended parameters

The TR-evo operation is configured by adjusting another set of parameters, called extended
parameters which can be accessed with the following procedure:
To access the extended configuration parameters, bring the bottom display to value
cfg
using the key
10
1 0
The display then shows the first extended parameter indicated by the parameter code
100
on the bottom display. If you do not want to edit the value, press the
the next parameter, otherwise the
1 1
the parameter in the temperature controller non-volatile memory.
16
key saves the timer in the temperature controller
key to go to the next parameter, otherwise the
key saves the timer in the temperature controller memory.
and the bottom display shows
tun
when the top display shows CFG and then press
and
key to go to the next parameter, otherwise
TO
keys edit the value and the
. If you
td
and
parameters that
TR
. If you do not
dr
to indicate the
10
key is used to
key allows you to
.
key to go to
key saves