System and alarm monitoring

When on, the temperature controller continuously controls operations are proceeding correctly
and if errors are found that prevent proper operation, blocks and signals the cause of the error.
Signalling is implemented via contact of a relay that signals the tool condition to the operating
machine, using an error number displayed on the numerical display, and transmitted instead of the
temperature on the serial interface.

Errors table and possible solutions

Error code
Description
1
Load power supply frequency outside limits;
this error highlights the protective fuse has blown or the power supply
frequency is outside the values permitted. Restore the fuse or check the
power supply line.
13
Timed:
in this mode, when the pre-heating input is on, it activates
temperature adjustment to the pre-heating temperature. Start
input activates the timed heating cycle which is composed of 2
phases. The first phase (indicated with the TD led on the display)
delays heating starting for the time set on the relevant timer. The
second phase (indicated with the TO led on the display) adjusts
time
time
the heating temperature for the time set on the relevant timer. At
the end of the cycle, the equipment waits for start input disabling
START
to re-start a new cycle. The cycle can be stopped at any time by
disabling the START signal.
CICLE
Pulse:
in this mode, the start input is used to start the timed cycle
which will only end on conclusion of the 3 phases composing it
The phases are: (4) delay, adjustment activates at the pre-
heating temperature, however heating is delayed for the time set
on the relevant timer. This time is used when it is not possible to
have the START signal activated at the right moment. (5)
time
time
Heating, the temperature is brought to the work value for the
START
time selected on the relevant timer. (6) Cooling, the heating
element is no longer powered and when the temperature is
below the value set on the relevant parameter or on expiry of
CICLE
the relevant timer, the cycle concludes by disabling the cycle
output.