8.
INSTALLATION OF ADDITIONAL FILTER STAGES
The addtional stage will be connected with two screws beside on the left of the main
filter stage. If you have already installed a main stage please close the water flow at the
T-Adapter (grey lever oblique to water flow direction). Please take off the hose from the
filter head (on left side) of the main stage. It is necessary to push down the small lock ring
to unlock the hose and pull it out at the same time.
1.
Please open carefully the cap of the filter head with a small screw driver
2.
Now you can see the holes for the screws
3.
Shorten the white hose to a proper lenght between the filter stages. We recommend
1,5cm minimum length
4.
Plug in the hose into both filter heads all the way to the stop.
5.
Now you can attach the filter head of the additional stage beside the main stage. We
recommend this chronological order as it is hard to fit in the short hoses when the
filter heads are mounted already.
6.
Now you can close the head by putting on the cap again. Please check of correct
positioning of the pins and press it together. Please plug in the water inlet hose
(which comes from the T-Adatper) into the head of the additional stage. If you need
more stage for anti lime scale for e. g. You can add the other stages in the same way.