Service Manual
7.17 Control Board
Part No.
Function
Failure Event
Effects
Error Code
Diagnostic
Color/Number of Wires
Table 20
7.18 Condensate Trap Assembly
Part No.
Function
Failure Event
Effects
Error Code
Diagnostic
Color/Number of Wires
Table 21
7.19 Air Pressure Switch
Part No.
Function
Failure Event
Effects
Error Code
Diagnostic
Color/Number of Wires
Table 22
1 8 |
7738007249 (Singular 5200)
7738007248 (Singular 4000)
To control each component and performance of unit.
Malfunction of control board.
Unit does not operate.
A component does not operate within the unit.
In case of the control board failure, the water heater does not
operate.
—
Visual inspection: Connection or breakage of water or burn marks on the
control board.
N/A
7738007273
Drain condensation, which is created while combusting.
Fail to drain condensation caused by clogged trap.
Condensation leakage into the unit.
Stop combustion.
Condensation leakage.
AD
Visual inspection: Connection or breakage of wires, check for
physical damage to the trap body.
Voltage Check: Check range of voltage shown below.
Green-Red: AC 24 V
7738007247 (Singular 5200)
7738007246 (Singular 4000)
Prevents operation of the unit due to unsafe condition. Back pressure or
blockage has occurred in the exhaust vent.
No operation of the unit.
Stop combustion.
No operation of the unit.
AE
Visual inspection: Connection or breakage of wires.
Voltage check: Check range of voltage shown below.
Green-Green: DC 5 V
Singular Combi Boiler - BTC 439002301 A (12.2021)