LG WCES6428F Installation Manual page 11

Combination wall oven
Hide thumbs Also See for WCES6428F:
Table of Contents

Advertisement

Available languages

Available languages

us_main.book.book Page 11 Thursday, December 9, 2021 8:44 AM
connection block. Failure to do so can result in
electrical shock, severe personal injury or death.
Cable from home power supply
a
Black wires
b
White wires
c
Red wires
d
Green (or bare) ground wires
e
4-wire flexible conduit from oven
f
1
Connect the oven ground (green) wire and
neutral (white) wire to the branch circuit
neutral (white or gray) wire, using a wire nut.
2
Connect the oven red wire to the branch
circuit red (L2) wire in accordance with local
codes, using a wire nut.
3
Connect the oven black wire to the branch
circuit black (L1) wire in accordance with local
codes, using a wire nut.
4
Install the junction box cover.
4-Wire Connection from Home Power
Supply
WARNING
• Only a 4-conductor power-supply cord kit rated
120/240 volts, 50 amperes and marked for use
with ranges with closed-loop connectors or open
spade lugs with upturned ends shall be used.
The white middle (neutral) wire of the power
cord or 4-wire conduit has to be connected to
the middle post of the main terminal block. The
other two wires of the power cord or conduit
have to be connected to the outside posts of the
main terminal connection block. The 4th ground
wire (green) must be connected to the frame of
the oven with the ground screw. Failure to do so
can result in electrical shock, severe personal
injury or death.
Cable from home power supply
a
Black wires
b
White wires
c
Red wires
d
Green (or bare) ground wires
e
4-wire flexible conduit from oven
f
1
Separate the oven ground and white wires if
necessary.
2
Connect the oven ground (green) wire to the
branch circuit ground (green) wire in
accordance with local codes, using a wire nut.
3
Connect the oven white wire to the branch
circuit neutral (white or gray) wire in
accordance with local codes, using a wire nut.
4
Connect the oven red wire to the branch
circuit red (L2) wire in accordance with local
codes, using a wire nut.
5
Connect the oven black wire to the branch
circuit black (L1) wire in accordance with local
codes, using a wire nut.
6
Install the junction box cover.
INSTALLATION
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents