CDI TRAXALL 770 User Manual page 7

Multi -source magnetic c pipeline pig location on and tracking system
Hide thumbs Also See for TRAXALL 770:
Table of Contents

Advertisement

DEVICES
OVERVIEW
TRAXALL 700 SERIES USER GUIDE
Magne c Flux Leakage (MFL) Pigs
Magne c Flux Leakage is a form of nondestruc ve inline inspec on that
detects corrosion, pi ng, missing metal, cracks, and/or other defects in
steel pipelines.
An MFL "smart pig" such as shown here is a common inline inspec on
tool:
DETECTOR
MAGNETIC POLES
MAGNETIC POLES
ODOMETER WHEELS
DATA RECORDER
As it travels through a pipeline, the magne c array magne zes the steel.
When defects are encountered, the magne c fi eld "leaks" from the
steel. This leakage fi eld is sensed by the magne c detector.
Field intensity and defect loca ons are usually stored by the unit's on-
y
board recorder.
Inline Inspec on (ILI) Tool Transmi ers
ILI transmi ers are similar in performance
and func on to the T-series transmi ers,
but in lieu of pressure housings, are
designed to work in conjunc on
with MFL pigs.