1 | Warnings & Precautions
Please read these instructions thoroughly before commencing installation.
Please check that all ancillary components are present and that the product has
not suffered any damage during transit. Make sure you are entirely happy with
the size, design and finish before starting installation.
Installation should be carried out by a qualified professional or other fully
competent person and in accordance with the relevant British and European
standards (EN60335:2008, EN12828:2003, EN12831:2003 and EN14336:2004), and all
applicable Building Regulations.
This towel rail has been pre-filled and adjusted for electrical standalone use. No
filling is required. Do not remove any of the seals as this might cause leakages and
void the warranty.
• When drilling or fixing into walls, floors or ceilings it is essential you check for
pipes and wires before commencing. Please ensure that you wear all
necessary personal protective equipment.
• Always switch off the electricity supply at the mains during installation,
cleaning and maintenance.
• Make sure that the voltage indicated on the rating label for this appliance
corresponds to your power outlet.
• Electrical safety is guaranteed only if the element is connected to a suitably
earthed electricity supply, according to the regulations in force.
• Do not use the device if you detect damage to the supply cable. If the supply
cable is damaged, it must be replaced by the manufacturer, its service agent
or similarly qualified persons to avoid a hazard.
• The wires must be connected in an electrical connection box which complies
with applicable standards.
• The towel rail will get very hot so it is not suitable for use in locations where
this could cause a hazard, such as places where infirmed persons or young
children will be present unsupervised.
• The element must be permanently connected to a suitable electricity supply
using the cable provided. The connection should be made via a fused spur in
accordance with IEE wiring regulations. If sited in a bathroom, the fused
connection unit must be located out of the reach of persons using the sink,
shower or bath.
Ecostrad_Fina-E_ V1.1_20092021