IKEA MATMASSIG Manual page 31

Hide thumbs Also See for MATMASSIG:
Table of Contents

Advertisement

Available languages

Available languages

ENGLISH
The mains cable is provided for a one-phase
connection.
Two-phase connection for maximum
power (7200 W)
1. Remove the cable end sleeve from black
and brown wires.
2. Remove an insulation of the brown and
black cable ends.
3. Apply a new wire end sleeve of 1.5 mm²
on each cable end (a special tool
required).
400V 2N ~
PE
N
220V-240V~
L2
L1
One-phase connection - 220 V - 240 V~
/ PE
N
L
Power limitation
Originally the appliance works at the highest
possible power level (7200 W).
To decrease or increase the power level:
1. Switch off the appliance.
2. Touch
for 3 seconds. The display
comes on and goes off.
3. Touch
for 3 seconds.
on.
4. Touch
. P 72 comes on.
5. Touch
or
power level.
Power levels
• P 72 — 7200 W
• P 15 — 1500 W
• P 20 — 2000 W
• P 25 — 2500 W
• P 30 — 3000 W
220V - 240V ~
PE
N
220V-240V~
L
Green - yellow
Blue and blue
Black and brown
or
comes
of the Timer to set the
220V-240V ~
N
L
Two-phase connection - 400 V 2 ~ N
Green - yellow
Blue and blue
Black
Brown
• P 35 — 3500 W
• P 40 — 4000 W
• P 45 — 4500 W
• P 50 — 5000 W
• P 60 — 6000 W
To confirm your selection wait until the
appliance switches off automatically.
If you accidentally press
a list of codes comes on. This is
only relevant for service
purposes. To leave this menu
touch
again or wait until the
appliance switches off
automatically.
Caution! Make sure that the
selected power fits to the house
installation fuses.
400V 2~N
/ PE
N
L1
L2
twice,
31
N
L1
L2

Advertisement