Step 2: Press "DONE" button for new setting to take effect immediately. If the "DONE" button is not pressed,
the new temperature setting will take effect in approximately 10 seconds.
Pressing the "NEXT" button instead of "DONE" will enter the display to show unused screens such as "Stack
----˚F, Outdoor ----˚F, % Rate (Shows percentage of full input rate for Lightoff rate), Outlet ----˚F, Inlet ----˚F,
Delta T ----˚F. These screens are not used in our application. Press DONE to exit this screen back to the
DHW setpoint display.
To Change Temperature Format in Display from F to C or ˚C to ˚F
Enter "Set-Up Mode" by pressing both UP/DOWN buttons together for 3 seconds.
Energy Cut Out (ECO)
An Energy Cut Out (ECO) is incorporated in the sensor and control board which will shut off all gas supply to
the burner if the water heater temperature exceeds 207°F (97.2°C). Should the ECO function (open), the water
temperature should be reduced to approximately 120°F (49°C) and a qualified service agent must be called to
place the water heater in operation. The water heater must have the problem corrected by a qualified service
agent before putting the water heater back in operation. It is recommended that all service work be performed
by a qualified service agency.