Installation

5
Installation
The tank is delivered fully assembled.
▶ Check that the tank is complete and undamaged.
5.1

Tank installation

5.1.1

Requirements for installation location

The material for positioning and fastening the floor-
standing boiler to the DHW tank is included in the scope
of delivery of the boiler-storage tank connecting line.
NOTICE: Risk of damage from inadequate load-bearing
capacity of the supporting substructure or unsuitable
floor surface!
▶ Ensure that the installation area is level and offers
sufficient load-bearing capacity.
NOTICE: Risk of damage from stress cracking and
corrosion!
▶ Position the DHW tank in a dry room free from the
risk of freezing.
▶ Install the tank only in closed-loop, unvented
hydronic heating systems.
▶ Never use open, vented expansion vessels for this
DHW tank.
NOTICE: If leaks can result in property damage or a drain
pan is required by law:
▶ Install an adequate drain pan.
▶ Follow the installation instructions of the drain pan
manufacturer.
▶ Place the DHW tank on a plinth if there is a risk that water may collect
at the installation site.
▶ The installation site must be a dry and frost-free room.
▶ Observe minimum wall clearances at installation location ( Fig. 6).
▶ Maintain a clearance of 2" (51 mm) from heated pipes and
combustible surfaces.
10
5.1.2

Wall clearances

Fig. 6
Recommended minimum wall clearances (illustrative)
5.1.3

Positioning the tank

▶ Cut the packaging film on the side opposite the "Tank top" sticker
( Fig. 7).
▶ Remove only the film you have cut out.
▶ Thread the 4 adjustable feet supplied [1] ~ 0.6...1 inch into the
threaded bushings provided for this purpose.
▶ Remove the wooden corner strips [3] from the tank underside.
1
Fig. 7
Cutting the packaging film and inserting the adjustable feet
[1]
Adjustable feet
[2]
Rear end of tank
[3]
Wooden corner strips
[4]
Front end of tank
▶ Tip the DHW tank over on the edge of the pallet and set it on its feet
( Fig. 8).
▶ Remove the remaining film, bottom and top of packaging and
wooden pallet. Raise the front and rear of the DHW tank slightly if
necessary to do this.
Logalux LT160/1 | LT200/1 | LT300/1 – 6 720 811 745 (2021/10)