Installation

Note:

Prepare

To ensure optimal function, consider the installation environment and the
following guidelines:
• For indoor use only. Operating temperature 0°C to 40°C
(32°F to 104°F), 5%–95% relative humidity (non-condensing).
• High density construction materials and large metal appliances or
fixtures in the space may disrupt wireless reception.
• Install the WTC within range of linked lighting controllers, 24 m (80 ft)
unobstructed view. Consider adding a repeater to extend the wireless
signal, if required.
• External antenna options include extension cables and a magnet-mount
antenna for installation locations with poor wireless reception.
• Can be surface-mounted or flush-mounted in an industry standard
two-gang electrical box (not provided). The box must be installed plumb
and square. Ensure it is clean and free of obstructions to accommodate
the cable if using an external antenna.
• Provide a 24 V power supply connection to the target two-gang
electrical box.
• Pull the plastic tab to activate the installed CR2032 battery. The battery
is not required to run the WTC, it is only used to maintain the time in
case of a power outage.
Note:
Wireless TimeClock Configuration Guide
Installation must follow all national and local codes for
electrical equipment.
An External Antenna Extension Kit is sold separately
through Echoflex, part number 8186K1001. Contact
Echoflex for more information.